FACTORY SOURCING HUB — POWER, AERIAL, CONTROL, SOLAR & BUILDING CABLE SOURCING Page reference: 0208 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0208-01 | Steel-reinforced aluminium conductor reference Aluminium area: 53.52 mm²; Steel area: 8.92 mm²; Total metallic area: 62.44 mm²; Approximate overall diameter: 10.11 mm 0208-02 | All-aluminium conductor Material direction: Aluminium strands; Construction: Bare stranded conductor 0208-03 | Aluminium-alloy conductor reference Published area: 15.48 mm²; Strand construction: 7 × 1.68 mm; Approximate overall diameter: 5.04 mm; Published linear mass: 42.7 kg/km 0208-04 | Steel-reinforced aluminium-alloy conductor Total metallic area: 163 mm²; Alloy / steel areas: 140 / 23 mm²; Approximate overall diameter: 16.6 mm 0208-05 | Alloy-reinforced aluminium conductor Material direction: Aluminium with aluminium-alloy reinforcement; Size / stranding: Confirm selected design 0208-06 | Bare copper conductor reference Nominal area: 25 mm²; Strand construction: 7 × 2.1 mm; Approximate overall diameter: 6.3 mm; Published DC resistance at 20 °C: 0.7563 Ω/km 0208-07 | Clad-steel and galvanised-strand directions Construction directions: Clad-steel or galvanised strand; Specification basis: Metal build, coating, strand and electrical requirements 0208-08 | 0.6/1 kV aerial bundled cable reference Core arrangement: 2 × 16 mm²; Conductor: Aluminium; Nominal insulation thickness: 1.2 mm; Published conductor DC resistance at 20 °C: 1.91 Ω/km 0208-09 | Copper concentric cable Published voltage direction: 0.6/1 kV; Main conductor: Class 2 copper; Concentric layer: Copper wires; Insulation options: XLPE or PVC by design 0208-10 | Aluminium concentric cable Published voltage direction: 0.6/1 kV; Main conductor options: Aluminium or selected aluminium alloy; Concentric layer: Copper wires 0208-11 | Wire-armoured XLPE power cable reference Published voltage: 0.6/1 kV; Selected core arrangement: 3 × 4 mm²; Nominal insulation / sheath: 0.7 / 1.8 mm; Approximate overall diameter: 16.5 mm 0208-12 | Tape-armoured PVC power cable reference Selected core arrangement: 3 × 4 mm²; Nominal insulation / sheath: 1.0 / 1.8 mm; Approximate overall diameter: 16.09 mm; Protection direction: Steel-tape armour 0208-13 | PVC-sheathed power cable reference Selected core arrangement: 1 × 4 mm²; Nominal insulation / sheath: 1.0 / 1.4 mm; Approximate overall diameter: 7.0 mm 0208-14 | Screened medium-voltage XLPE reference Published rated voltage: 6/10 kV (11 kV); Selected nominal area: 25 mm²; Nominal insulation thickness: 3.4 mm; Approximate single-core diameter: 19.6 mm 0208-15 | Medium-voltage aerial construction Listed conductor options: AAC, AAAC or ACSR by design; Insulation direction: XLPE or LDPE; Outer layer: Optional sheath by construction 0208-16 | Flexible control-cable reference Published voltage direction: 450/750 V; Conductor direction: Copper, class selected by item; Insulation options: PVC or XLPE by design; Shielding directions: Unscreened, braid or copper-tape screen 0208-17 | Rigid PVC single-core wire reference Selected nominal area: 2.5 mm²; Published strand count: 1; Nominal insulation thickness: 0.8 mm; Approximate overall diameter: 3.38 mm 0208-18 | Flexible PVC single-core wire reference Selected nominal area: 2.5 mm²; Published strand count: 50; Nominal insulation thickness: 0.8 mm; Approximate overall diameter: 3.70 mm 0208-19 | Nylon-jacketed building-wire direction Published voltage direction: 600 V; Insulation / jacket: PVC / nylon; Conductor options: Copper or selected aluminium alloy 0208-20 | Crosslinked-insulation building wire Published voltage direction: 600 V; Core arrangement: Single core; Insulation direction: Crosslinked polyethylene 0208-21 | Multi-core flexible PVC cord reference Published voltage: 300/500 V; Selected core arrangement: 3 × 1.5 mm²; Nominal insulation thickness: 0.7 mm; Published overall diameter: 8.1 mm 0208-22 | Twin-and-earth cable direction Construction direction: Twin insulated cores with protective conductor; Insulation options: PVC or XLPE by design; Sheath options: PVC or low-smoke compound by item 0208-23 | Low-smoke insulated-wire direction Conductor direction: Copper, class 1 / 2 / 5 by item; Insulation direction: Specified thermoplastic compound; Published operation reference: 70 °C 0208-24 | Flexible rubber cable reference Published voltage: 450/750 V; Selected core arrangement: 3 × 2.5 mm²; Nominal insulation thickness: 0.9 mm; Nominal sheath thickness: 1.8 mm 0208-25 | Welding-cable reference Selected nominal area: 25 mm²; Nominal sheath thickness: 2.0 mm; Published outer-diameter range: 10–13 mm; Published resistance reference: 0.7800 Ω/km 0208-26 | Single-core photovoltaic cable reference Selected core / area: 1 × 4 mm²; Nominal insulation / sheath: 0.7 / 0.8 mm; Published DC resistance at 20 °C: 5.09 Ω/km; Conductor: Class 5 tinned copper 0208-27 | Twin-core photovoltaic cable reference Selected core / area: 2 × 4 mm²; Nominal insulation / sheath: 0.7 / 0.8 mm; Published DC resistance at 20 °C: 5.09 Ω/km; Conductor: Class 5 tinned copper 0208-28 | Switch and socket range enquiries Product directions: Switches and sockets; Mounting / ratings: Confirm selected item and destination 0208-29 | Mineral-insulated, high-voltage and cable-material projects Scope: Project-specific construction or material; Quotation basis: Technical schedule and current feasibility This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.