FACTORY SOURCING HUB — LOW-VOLTAGE PROTECTION, MOTOR CONTROL, SMART POWER & SOLAR ELECTRICS Page reference: 0215 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0215-01 | 6 kA modular MCB reference Current choices: 6, 10, 16, 20, 25, 32, 40, 50, 63 A; Poles / trip options: 1, 2, 3, 4 poles; B, C or D; Voltage / frequency: 1P 230/400 V AC; 2–4P 400 V AC; 50/60 Hz; Catalogue breaking capacity: 6 kA; Published reference standard: IEC 60898-1 0215-02 | 1P+N RCBO reference Current choices: 6, 10, 16, 20, 25, 32, 40 A; Supply / poles: 230 V AC; 50/60 Hz; 1P+N; Residual-current choices: 30, 100 or 300 mA; AC or A type variants; Breaking-capacity references: Icn 6 kA under IEC 61009-1; Icu 10 kA under IEC 60947-2; Trip choices: B or C 0215-03 | Residual-current breaker up to 100 A Current choices: 10, 16, 25, 40, 63, 80, 100 A; Pole / voltage references: 1P+N / 230 V AC; 3P+N / 380 V AC; Frequency: 50/60 Hz; Residual-current choices: 10, 30, 100 or 300 mA; Waveform / timing: AC, A or B variants; instantaneous or selective variants—confirm combination 0215-04 | PC-class transfer-switch reference Class / series limit: PC class; up to 3,200 A; Rated supply reference: 400 V AC; 50/60 Hz; Controller supply described: 220 V AC; To specify: Rated version, poles, transfer sequence, interfaces and interlocks 0215-05 | Thermal-magnetic MCCB frame range Listed frame-current sizes: 63, 100, 250, 400, 630 and 800 A; Trip direction: Thermal-magnetic; Pole directions: Three-pole and four-pole ordering sections; To specify: Icu/Ics at operating voltage, trip settings, terminals and accessories 0215-06 | Type 2 surge-protection direction Device direction: Type 2 surge protective device; To specify: Uc, In/Imax, Up, poles, network and backup protection; Configuration: Confirm cartridge, status indication and any remote contact 0215-07 | Modular plastic distribution-box reference Module counts: 4, 6, 8, 12, 18, 24, 36; Row arrangement: 4–18 modules: one row; 24: two rows; 36: three rows; Published protection designation: IP30; Materials: HIPS body; SAN door for 4–18 modules; PC door for 24/36; Finish directions: RAL 9003 white / RAL 7035 grey; door options subject to version 0215-08 | Thermal overload-relay selection range Catalogue family coverage: 0.1–93 A across different variants; To specify: Individual adjustment range, trip class, reset and auxiliary contacts; Compatibility: Verify the exact contactor and mounting arrangement 0215-09 | Motor-protection circuit-breaker range Catalogue family coverage: 0.1–80 A across different variants; Accessory directions: Undervoltage/shunt release, auxiliary contact, alarm and enclosure; To specify: Motor current, starting duty, coordination and actual breaking rating 0215-10 | Connected electrical gateway reference Device-side communication: RS485; Catalogue device limit: Up to 32 compatible smart switches; Mounting: 35 mm DIN rail; Version directions: 4G, Wi-Fi, Ethernet LAN, NB-IoT or GPRS; To specify: Actual version, supply, platform, permissions and compatible devices 0215-11 | Smart miniature-breaker direction Connectivity condition: Remote operation with a compatible smart gateway; Published reference standard: IEC 60898-1; To specify: Poles, current, protection settings, measured data and network-failure behaviour 0215-12 | Photovoltaic combiner-box direction Application: PV array to inverter connection; Configuration brief: String count, DC voltage/current, protection and communication; To specify: Enclosure, input/output connectors, polarity, drawing and installation conditions 0215-13 | DC miniature-breaker reference Current choices: 6, 10, 16, 20, 25, 32, 40, 50, 63 A; Poles: 1, 2, 3 or 4; Catalogue operating-voltage mapping: 1P 250 V DC; 2P 500 V DC; 3P 750 V DC; 4P 1,000 V DC; Trip options: B or C; use the DC-specific curves; Published reference standard: IEC 60947-2 0215-14 | Matched breaker auxiliary modules Function directions: Position contact, alarm, combined contact/alarm, undervoltage and shunt release; Published insulation reference: 500 V AC; Frequency reference: 50/60 Hz; To specify: Host device, actual accessory, control supply and contact rating This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.