FACTORY SOURCING HUB — OVERHEAD CONDUCTORS, POWER-LINE HARDWARE & ELECTRICAL EQUIPMENT SOURCING Page reference: 0216 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0216-01 | 39.3 mm² all-alloy conductor reference Construction: 7 × 2.67 mm; Calculated area: 39.3 mm²; Overall diameter: 8.01 mm; Approximate mass: 107.32 kg/km; Calculated DC resistance at 20°C: 0.8547 Ω/km; Calculated breaking load: 12.50 kN 0216-02 | Steel-reinforced aluminium conductor reference Aluminium area: 40 mm²; Steel area: 6.67 mm²; Total area: 46.67 mm²; Strands: Al 6 × 2.91 mm; steel 1 × 2.91 mm; Overall diameter: 8.74 mm; Approximate mass: 161.5 kg/km; Rated strength: 14.40 kN; Listed DC resistance: 0.7174 Ω/km 0216-03 | Nominal 100 mm² all-aluminium reference Nominal area: 100 mm²; Calculated area: 106 mm²; Construction: 7 × 4.39 mm; Overall diameter: 13.17 mm; Approximate mass: 290 kg/km; Calculated DC resistance at 20°C: 0.2702 Ω/km; Calculated breaking load: 16 kN 0216-04 | ABC with 25 mm² phase conductors Phase construction: 3 × 25 mm² aluminium; Neutral reference: 54.6 mm² alloy; Phase insulation: XLPE, 1.4 mm listed; Phase DC resistance at 20°C: ≤1.20 Ω/km in reference table 0216-05 | ABC with 35 mm² phase conductors Phase construction: 3 × 35 mm² aluminium; Neutral reference: 54.6 mm² alloy; Phase insulation: XLPE, 1.6 mm listed; Phase DC resistance at 20°C: ≤0.868 Ω/km in reference table 0216-06 | ABC with 50 mm² phase conductors Phase construction: 3 × 50 mm² aluminium; Neutral reference: 54.6 mm² alloy; Phase insulation: XLPE, 1.6 mm listed; Approval basis: Current project-specific cable schedule 0216-07 | Seven-strand stay-wire reference Strands: 7; Individual strand diameter: 4 mm; Calculated tensile strength: 101 kN; Confirmation: Wire grade, coating and termination tests 0216-08 | Nominal 16 mm eye-bolt direction Nominal diameter: 16 mm; Listed length options: 120, 150, 200, 250, 300 or 400 mm; To specify: Thread, eye geometry, material, finish and proof load 0216-09 | Square base-plate reference Listed size: 300 × 300 × 6 mm; Required approval: Hole drawing, material and surface treatment 0216-10 | Long crossarm reference Listed length: 2500 mm; To define: Section, hole layout, material and loading 0216-11 | Outdoor air-break switch direction Listed rated-voltage range: 30–36 kV; Listed current range: 400–1250 A; Reference creepage range: 660–900 mm; Selection: Exact variant and withstand schedule required 0216-12 | 33 kV surge-arrester reference Rated voltage: 33 kV rms; Maximum continuous operating voltage: 26.8 kV rms; Approval: System earthing, insulation coordination and verified tests 0216-13 | 33 kV cutout reference Rated voltage: 33 kV; Rated current: 100 A; Listed breaking current: 8000 A; Listed creepage: 820 mm; Listed impulse withstand: 170 kV; Listed power-frequency withstand: 70 kV 0216-14 | 36 kV polymeric pin-insulator reference Rated voltage: 36 kV; Cantilever strength: 8 kN; Structure height: 440 mm; Insulating distance: 320 mm; Minimum creepage: 1000 mm; Lightning impulse withstand: 185 kV; Wet power-frequency withstand: 95 kV 0216-15 | 35 kV suspension-insulator reference Rated voltage: 35 kV; Mechanical load: 70 kN; Structure height: 650 mm; Insulating distance: 450 mm; Creepage: 1225 mm; Lightning impulse withstand: 230 kV; Wet power-frequency withstand: 95 kV 0216-16 | Preformed tension and suspension fittings Options: Tension, suspension, armour, splicing and binding directions; Required input: Conductor construction and mechanical drawing 0216-17 | Transformer and distribution equipment brief Directions: Distribution/power transformers; dry-type; accessories; Required input: kVA, ratio, vector group, cooling and tests 0216-18 | Solar and outdoor-lighting project brief Directions: Solar systems, street and flood lighting, controls; Required input: Load profile, photometry, autonomy and environmental duty 0216-19 | Hydraulic cable and busbar tooling brief Directions: Crimping, cutting, punching and busbar preparation; Required input: Material, section, operation and matching dies 0216-20 | Operating-rod and construction-tool brief Directions: Fixed/telescopic operating rods and construction tools; Required input: Working duty, reach, insulation and required tests This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.