FACTORY SOURCING HUB — CIRCUIT BREAKERS, MOTOR CONTROL, DISTRIBUTION BOXES & ACCESSORIES Page reference: 0217 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0217-01 | 6 kA or 10 kA modular MCB reference Current choices: 6, 10, 16, 20, 25, 32, 40, 50, 63 A; Pole options: 1P, 2P, 3P, 4P; Catalogue Icn versions: 6 kA or 10 kA, depending on version; Characteristics / frequency: B, C or D; 50–60 Hz; Width: 18 mm per pole 0217-02 | Higher-current modular breaker reference Rated-current schedule: 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 A; Poles: 1P–4P; Catalogue Icn versions: 10 kA or 15 kA; Characteristic options: B, C, D; Width / height / depth: 27 mm per pole; 90 mm high; 75.5 mm deep 0217-03 | 18 mm phase-and-neutral RCBO reference Pole arrangement / width: 1P+N; 18 mm; Rated-current table reference: 40 A; Supply: 230 V; 50–60 Hz; Trip curve: B or C; Catalogue breaking reference: 6 kA 0217-04 | 125 A frame fixed MCCB reference Frame / poles: 125 A frame; 3P or 4P; Operating voltage: 400 V; Icu / Ics: 50 kA / 37.5 kA, S version at 400 V; Insulation / impulse reference: Ui 750 V; Uimp 10,000 V; Trip construction: Fixed thermal-magnetic 0217-05 | 250 A frame adjustable MCCB reference Frame / poles: 250 A frame; 3P or 4P; Operating voltage: 400/415 V; Icu / Ics: 50 kA / 37.5 kA, S version; Thermal setting reference: 70–100% of In; Magnetic setting reference: 5–10 × In 0217-06 | Electronic-release MCCB direction Family current reference: 100–1600 A AC, with the actual frame selected separately; Overload setting reference: 40–100% of In; Instantaneous setting reference: 1.5–12 × In; Required selection: Exact trip unit, current rating, poles and fault ratings 0217-07 | 160 A frame residual-current MCCB reference Frame / poles: 160 A frame; 4P; Operating voltage: 400/415 V; Icu / Ics: 50 kA / 37.5 kA, S version; Residual-current selections: 100, 300, 500 mA; Delay selections: 50, 500, 800 ms 0217-08 | 1000 A frame air breaker reference Frame / current selections: 1000 A frame; 200, 400, 630, 800, 1000 A; Poles: 3P or 4P; At 400 V: Icu 42 kA; Ics 30 kA; Icw 20 kA; At 690 V: Icu 25 kA; Ics 20 kA; Icw 20 kA; Normal open mounting: IP30 catalogue reference 0217-09 | AC-3 contactor family reference Main-circuit family range: 9–370 A; Motor-power family reference: 4–200 kW at 400 V, AC-3; Quote details: Motor current, coil voltage, auxiliary contacts and duty 0217-10 | 6–10 A adjustable motor-protection reference Adjustable current: 6–10 A; Motor-power example: 4 kW at 380/415/440 V, AC-3; Alternative voltage example: 2.2 kW at 220 V, AC-3; Required coordination: Motor current, starting duty and upstream protection 0217-11 | 12-way indoor surface enclosure reference Way count / mounting: 12 ways; surface mounting; Catalogue enclosure protection: IP40; Reference carton quantity: 20 pieces; Reference carton size: 52 × 42.5 × 54 cm; Reference gross / net weight: 15.8 kg / 12.3 kg per carton 0217-12 | 12-way sealed distribution-box reference Way count: 12 ways; Catalogue enclosure protection: IP65; Reference carton quantity: 20 pieces; Reference carton size: 57 × 41.5 × 53.5 cm; Reference gross / net weight: 16.3 kg / 15.3 kg per carton 0217-13 | Busbar joint-cover direction Joint geometries: L, T and straight forms; Catalogue voltage-class directions: 1 kV, 10 kV and 35 kV; separate selections; Required match: Busbar section, joint layout, cover dimensions and shrink procedure 0217-14 | Undervoltage-release control options Listed control-voltage alternatives: AC 380 V; AC 220 V; DC 110 V; DC 220 V; Accessory function: Undervoltage release; Required host information: Breaker frame, mounting and control-circuit drawing This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.