FACTORY SOURCING HUB — CIRCUIT PROTECTION, EV CHARGING, DISTRIBUTION & INDUSTRIAL CONTROLS Page reference: 0220 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0220-01 | Modular 1–63 A MCB direction Current choices: 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 A; Curve options: B, C, D; Module width: 17.8 mm per pole; Terminal reference: 16 mm² flexible or 25 mm² rigid; Mounting: 35 mm DIN rail 0220-02 | 63–125 A modular protection direction Current choices: 63, 80, 100, 125 A; Poles: 1P, 2P, 3P, 4P; Multipole operating voltage: 400/415 V AC for 2P–4P; Module width: 27 mm per pole 0220-03 | Two- or four-pole smooth-DC residual-current direction Current choices: 16, 25, 32, 40, 50, 63 A; Two-pole voltage: 230/240 V AC; Four-pole voltage: 400/415 V AC; Sensitivity selections: 30, 100, 300 mA; Terminal reference: Cables up to 35 mm² 0220-04 | Compact electronic RCBO reference Current choices: 6, 10, 13, 16, 20, 25, 32, 40 A; Operating voltage: 230/240 V AC; Sensitivity selections: 10, 30, 100, 300 mA; Curve options: B or C; Listed dimensions: 17.8 × 72.7 × 89 mm 0220-05 | Arc-fault and RCBO combined reference Current choices: 6, 10, 16, 20, 25, 32, 40 A; Operating voltage: 230/240 V AC; Catalogue breaking reference: 6 kA; Sensitivity selections: 10, 30, 100, 300 mA; Listed dimensions: 17.8 × 78.2 × 117.8 mm 0220-06 | Connected residual-current MCCB direction Listed current settings: 200, 225, 250, 315, 350, 400, 500, 630 A; Supply reference: 400 V AC; 50 Hz; Residual-current settings: 100, 200, 300, 500, 800, 1000 mA; Residual-current characteristic: AC type in the selected table; Communication direction: RS-485; protocol and integration to be confirmed 0220-07 | High-current draw-out air breaker direction Rated-current selections: 5000, 6300, 7500 A; Supply schedule: 380, 400, 415, 440 V AC; 50/60 Hz; Installation reference: Draw-out; 3P or 4P; Connection direction: Horizontal or vertical 0220-08 | DC modular breaker reference Current choices: 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63 A; Single-pole DC reference: 120 V DC; 2P/3P/4P DC reference: 240 V DC, subject to specified connection; Catalogue breaking reference: 6 kA; Module width: 17.8 mm per pole 0220-09 | 1500 V DC moulded-case reference Current choices: 250, 320, 400, 450, 500, 630 A; Operating / insulation voltage: Ue 1500 V DC; Ui 1600 V; Icu reference: 20 kA at 1500 V; T = 10 ms; Ics reference: 20 kA at 1500 V; T = 10 ms; Listed dimensions: 98 × 310 × 130 mm 0220-10 | Photovoltaic DC surge-protection direction PV voltage selections: 500, 1000 or 1500 V DC; Nominal discharge current In: 20 kA, 8/20 µs; Maximum discharge current Imax: 40 kA, 8/20 µs; Module width: 18 mm per pole; Mounting: 35 mm DIN rail 0220-11 | 7 kW plug-and-charge AC box Power / current: 7 kW; 32 A; Nominal AC supply: 220 V; L+N+PE; Operation: Plug and charge; Cable option: 5 m, optional; Listed enclosure dimensions: 180 × 130 × 120 mm 0220-12 | Dual-plug AC charging direction Station output reference: 44 kW; User interface: 4.3-inch display in parameter table; Networking directions: Ethernet, 4G, Wi-Fi; Cable option: 3.5 m in parameter table; confirm final configuration; Nominal AC supply reference: 380 V AC; confirm phases, input current and power allocation 0220-13 | 120 or 180 kW DC charging direction Output selections: 120 or 180 kW DC; Nominal AC input: 380 V AC; Display reference: 7-inch touchscreen in parameter table; Networking directions: Ethernet, 4G, Wi-Fi; Listed enclosure dimensions: 720 × 557 × 1700 mm 0220-14 | Indoor modular enclosure range Module selections: 6, 8, 12, 18, 24, 36, 54; Row layout: 1 row for 6–18; 2 rows for 24/36; 3 rows for 54; Catalogue enclosure protection: IP30; Mounting: Surface or flush; Materials listed: PS or ABS body; PC door 0220-15 | 115 A AC-3 contactor example AC-3 current: 115 A at Ue ≤400 V; AC-4 current: 52 A at Ue ≤400 V; AC-3 motor-power example: 55 kW at 380/400 V; Conventional thermal current Ith: 200 A; Frequency reference: 50/60 Hz 0220-16 | Class 10A thermal overload-relay direction Trip-class reference: 10A; Catalogue protection: IP20; Ambient reference: −5 to +40 °C; Installation direction: Matched direct mounting under contactor; Selection required: Current-setting range and host combination 0220-17 | Panel-control component direction Panel opening: 22.5 mm diameter in parameter table; Listed contact-current references: 6 A at 230 V AC; 0.3 A at 230 V DC; Insulation voltage: Ui 400 V; Contact directions: 1NO, 1NC, 1NO+1NC This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.