FACTORY SOURCING HUB — CIRCUIT PROTECTION, SWITCHING, DISTRIBUTION & ELECTRICAL ACCESSORIES SOURCING Page reference: 0225 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0225-01 | DIN-rail miniature-breaker reference Poles: 1, 2, 3 or 4; Rated voltage: 240/415 V AC; Current options: 1–63 A in listed steps; Trip curves: B, C or D; Listed Icn options: 4500 or 6000 A; Frequency: 50/60 Hz; Mounting: 35 mm DIN rail or panel 0225-02 | Residual-current breaker reference Mechanism options: Electromagnetic or electronic; Residual types: A or AC; Poles: 2 or 4; Rated currents: 25, 40 or 63 A; Voltage: 240/415 V AC; Sensitivity options: 10, 30, 100, 300 or 500 mA; Conditional current Inc: 3000 A 0225-03 | Single-module RCBO reference Current direction: Up to 40 A; Trip curve: C; Listed breaking capacity: 10 kA; Width description: One module; Neutral: Solid neutral; Sample table configuration: 16 A /0.03 A residual current 0225-04 | Moulded-case breaker reference Insulation voltage: 660 V; Operating direction: 380 V AC or below; Frequency: 50 Hz; Family current ceiling: 800 A; Poles: 3 or 4 by variant 0225-05 | Air circuit-breaker reference Frequency: 50 Hz; Voltage directions: 400 or 690 V AC; Family current direction: 400–6300 A; Frames: 2000,3200 or 6300 A; To confirm: Release, breaking duty and installation 0225-06 | AC motor-contactor reference Selected reference AC-3 current: 9 A; Selected reference AC-4 current: 3.5 A; Coil directions: Separate 50,60 or 50/60 Hz options; To confirm: Control voltage and motor-duty table 0225-07 | Magnetic motor-starter direction Frequency: 50 or 60 Hz; Application voltage ceiling: 550 V AC; Required input: Motor load, coil, relay and reset 0225-08 | Low-voltage HRC fuse-and-base direction Reference family: Fuse links and matched bases; Voltage options in catalogue: 500/600 V on selected sizes; Required input: Current, fuse class, base and dimensions 0225-09 | Daily time-switch reference Timing range: 24 h; Minimum setting: 30 minutes; Supply options: 110 or 230 V AC; Published contact reference: 200 V AC,16 A; Reserve direction: 150 h, selected version 0225-10 | General-purpose micro-switch direction AC control direction: 50/60 Hz; up to 380 V; 100 VA; DC control direction: Up to 220 V; 10 W; To confirm: Contact form, actuator and terminals 0225-11 | Universal changeover-switch direction Directions: Rotary/universal changeover; Required input: Contact chart, voltage, utilisation duty and mounting 0225-12 | Weather-protected isolator direction Pole directions: 1,2 or 3; Current range: 20–80 A; Dimensions reference: 165 ×82 ×85 mm; Conduit directions: 20 or 25 mm; To confirm: Ingress rating, duty and installation 0225-13 | Panel control and indication direction Mounting direction: 22 mm fixing; Actuator directions: Flush,mushroom,selector and key return; To define: Colour, lamp supply, contact blocks and stop function 0225-14 | Single-phase energy-meter direction Frequency: 50 Hz; Voltage reference: 220 V; Accuracy-class reference: 2; To define: Current range, mounting and destination approval 0225-15 | Protected distribution-box reference Listed protection direction: IP 55; Way options: 5,8,12 or 18; Eight-way dimension reference: 185 ×105 ×185 mm, L/W/H as published; Required input: Circuits, devices, entries and installation 0225-16 | Twelve-pole terminal-block reference Reference current: 5 A; Conductor-area reference: 6 mm²; Poles: 12; Plastic options: PP,PE orPA 0225-17 | Industrial plug reference Current: 16 A; Poles: 3; Voltage: 220–240 V AC; Earth contact: 6h; Protection direction: IP 44 0225-18 | Ratchet crimp-tool reference Capacity: 0.5–6.0 mm²; Listed gauge range: 22–10 AWG; Length: 230 mm; Weight: 0.6 kg 0225-19 | Single-phase relay voltage-regulator direction Input: 140–260 V; Output reference: 220 V ±8%; Frequency: 50–60 Hz; Phase: Single; VA-size directions: 500–12000 VA catalogue options 0225-20 | Withdrawable switchgear-cubicle direction Directions: Withdrawable cubicle, drawers and operating mechanisms; Required input: Electrical duty, busbar, circuits, dimensions and tests 0225-21 | LED area-fixture reference Input: 90–260 V AC; Power: 50 W; Listed luminous flux: 3750 lm; Colour temperature: 5000–6000 K; Listed colour rendering: Ra 80; Beam reference: 80°; Protection direction: IP 65 0225-22 | Medium-voltage arrester reference Rated voltage: 33 kV; Continuous operating voltage: 26.7 kV; Nominal discharge class: 5 kA; Required input: System, impulse duties and exact housing design 0225-23 | Medium-voltage cutout direction Catalogue voltage directions: 10–38 kV across distinct ranges; Housing direction: Porcelain variants; Required input: System current, interruption duty and mounting 0225-24 | Regional GFCI receptacle direction Supply direction: 120 V AC; Current options: 15 or 20 A; Poles/wires: 2 poles,3 wires; Interface directions: 5-15R or 5-20R variants This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.