FACTORY SOURCING HUB — MODULAR BREAKERS, RESIDUAL-CURRENT PROTECTION, SURGE DEVICES & ISOLATION SOURCING Page reference: 0228 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0228-01 | Compact AC breaker reference Current direction: 1–40 A in listed steps; Voltage options: 220/230/240 V; Poles: 1P+N; Published ultimate/service values: 6/6 kA; Curves: B, C or D; Protection direction: IP20 0228-02 | Multi-pole AC breaker reference Current direction: 6–63 A in listed steps; Voltage options: 230/240 or 400/415 V; Pole options: 1, 2, 3, 4;1P+N;3P+N; Published ultimate/service values: 6/6 kA; Frequency: 50/60 Hz; Curves: B, C or D 0228-03 | DC miniature-breaker reference Current direction: 1–63 A in listed steps; Pole options: 1, 2, 3 or 4; Single-pole voltage options: 110/125/220/250 V DC; Published Icu/Ics: 10/7.5 kA; Four-pole voltage direction: 880/1000 V DC, exact wiring to confirm 0228-04 | 6 kA combined residual/overcurrent reference Current direction: 6–40 A in listed steps; Voltage: 230/240 V; Poles: 1P+N; Published Icu/Ics: 6/6 kA; Sensitivity options: 10, 30, 100 or 300 mA; Residual types: AC or A; Curves: B or C 0228-05 | 10 kA combined residual/overcurrent reference Current direction: 6–40 A in listed steps; Voltage: 240 V; Poles: 1P+N; Published Icu: 10 kA; Published Ics: 7.5 kA; Sensitivity options: 10, 30, 100 or 300 mA; Residual types: AC or A 0228-06 | AC/A residual-only breaker reference Instantaneous current options: 16, 25, 40, 63, 80 or 100 A; Time-delay current options: 40, 63, 80 or 100 A; Voltage options: 240 or 415 V; Poles: 1P+N or 3P+N; Sensitivity: 30, 100 or 300 mA; Residual types: AC or A; Conditional Inc/IΔc: 10 kA; backup protection required 0228-07 | Type B residual-only reference Current options: 16, 25, 40, 63 or 80 A; Voltage options: 230/240 or 400/415 V; Poles: 1P+N or 3P+N; Sensitivity: 30, 100 or 300 mA; Residual type: B; Conditional Inc/IΔc: 10 kA; not an RCBO Icu 0228-08 | EV-related combined protection reference Current direction: 6–63 A in listed steps; Voltage: 230/240 V; Poles: 1P+N; AC residual reference: 30 mA, Type A; DC residual reference: 6 mA; Published Icu/Ics: 6/6 kA 0228-09 | EV-related residual-only direction Current options: 16, 25, 40 or 63 A; Voltage options: 230/240 or 400/415 V; Poles: 1P+N or 3P+N; Residual reference: 30 mA; DC residual reference: 6 mA; To confirm: Waveform tests and coordinated overcurrent protection 0228-10 | Arc-fault combined-device reference Current direction: 6–40 A in listed steps; Voltage: 230/240 V; Poles: 1P+N; Residual type/sensitivity: A/30 mA; Published Icu/Ics: 10/7.5 kA; Listed overvoltage threshold: 275 V 0228-11 | Modular-contactor reference Current options: 20, 25, 40, 63, 80, 100 or 125 A; Operational voltage reference: 230/400 V; Control-voltage options: 24, 48, 110 or 230 V; Width options: 1, 2 or 3 modules; Listed categories: AC-1, AC-3, AC-7a, AC-7b, AC-5b 0228-12 | Extended modular-contactor direction Current options: 20, 25, 40, 50, 63, 80, 100 or 125 A; Control-voltage options: 24, 48, 110 or 230 V; Module widths: 1, 2, 3 or 6; Operational voltage reference: 230/400 V 0228-13 | MOV surge-protection reference Nominal discharge current: 20 kA, 8/20 μs; Maximum discharge current: 40 kA, 8/20 μs; Selected continuous voltage: 275 V; Selected protection level: ≤1.3 kV; Protection direction: IP20; Material direction: PA66 0228-14 | Lower-discharge surge-protection reference Nominal discharge current: 10 kA, 8/20 μs; Maximum discharge current: 20 kA, 8/20 μs; Continuous-voltage options: 275, 320, 385 or 420 V;neutral/earth 255 V; Protection direction: IP20 0228-15 | Modular isolator reference Current options: 63, 80, 100 or 125 A; Voltage options: 230/240 or 400/415 V; Poles: 1, 2, 3 or 4; Short-time withstand Icw: 1500 A for 1 s; Making capacity Icm: 2500 A; Protection direction: IP20 0228-16 | Manual changeover reference Current options: 6, 10, 16, 20, 25, 32 or 40 A; Voltage: 240/415 V; Poles: 1, 2, 3 or 4; Short-time withstand Icw: 480 A for 1 s; Making capacity Icm: 800 A; Utilisation category: AC-22A 0228-17 | Alternative manual changeover reference Current options: 6, 10, 16, 20, 25, 32 or 40 A; Voltage: 240/415 V; Poles: 1, 2, 3 or 4; Short-time withstand Icw: 680 A for 1 s; Making capacity Icm: 800 A; Utilisation category: AC-22A 0228-18 | Bell/control transformer direction Primary voltage options: 230/240 V; Frequency: 50/60 Hz; Protection direction: IP20; Selection input: Secondary voltage, winding diagram and VA duty 0228-19 | AC or DC signal-lamp direction AC voltage options: 24, 48, 110 or 230 V; DC voltage options: 24, 48, 110 or 230 V; Lamp source: LED; Listed lamp capacity: 0.8 W; Colours: Red, green, blue, yellow or clear; Protection direction: IP20 0228-20 | Modular fuse-holder direction Thermal current reference: 32 A; Voltage options: 230/240 or 400/415 V; Poles: 1, 2, 3 or 4; Fuse-link sizes: 8.5 ×31 or 10 ×38 mm; Insulation voltage: 600 V 0228-21 | Auxiliary indication and release brief Directions: Auxiliary contact, alarm indication, shunt and voltage-related release; To define: Compatible host, contact/control ratings and mounting 0228-22 | Busbar and protective-accessory brief Directions: Pin/fork busbars, handle locks, screw covers and barriers; To define: Dimensions, rating, compatibility and installation This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.