FACTORY SOURCING HUB — WELDING, BLOWERS & MECHANICAL COMPONENTS SOURCING Page reference: 0314 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0314-01 | Compact wire-fed welding configuration Quotation fields: Current supply, process, output range, duty conditions, feeder and operating kit 0314-02 | Gas-shielded 40–250 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 10.7 A; gas-shielded 12.7 A; Input capacity: MMA 7.1 kVA; gas-shielded 8.4 kVA; Output-current adjustment: MMA 20–200 A; gas-shielded 40–250 A; Open-circuit voltage: 50 V; Duty-cycle reference: 60%; current and temperature conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 490×210×385 mm; Weight: 18 kg 0314-03 | Gas-shielded 50–315 A welder Supply: Three-phase 380 V ±15%; Output-current adjustment: MMA 20–250 A; gas-shielded 50–315 A; Open-circuit voltage: 50 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 550×290×400 mm; Weight: 26 kg; Controls / configuration: IGBT inverter; inductance adjustment; display; arc-start/burnback and slow wire-feed settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit.; Electrical-input requirement: Confirm the actual input-current and supply-capacity schedule for the selected process and operating point 0314-04 | Gas-shielded 50–200 A welder Supply: 220 V ±15%; Input current: MMA 30.9 A; gas-shielded 35.2 A; Input capacity: MMA 6.8 kVA; gas-shielded 7.7 kVA; Output-current adjustment: MMA 20–160 A; gas-shielded 50–200 A; Open-circuit voltage: 52 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.73; Wire feeder: Integrated; Wire diameter: 0.6–1.0 mm; Insulation designation: F; Dimensions: 520×280×530 mm; Weight: 25.5 kg; Controls / configuration: Integrated feeder; wheeled body; inductance and arc-start/burnback settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-05 | Gas-shielded 50–250 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 14.4 A; gas-shielded 12.7 A; Input capacity: MMA 9.5 kVA; gas-shielded 8.4 kVA; Output-current adjustment: MMA 20–250 A; gas-shielded 50–250 A; Open-circuit voltage: 50 V; Duty-cycle reference: 25%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Integrated; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 520×280×530 mm; Weight: 27.2 kg; Controls / configuration: Thin-sheet and spot-welding direction; inductance and slow-feed settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-06 | 40–250 A pulse welder Supply: Three-phase 380 V ±15%; Output-current adjustment: 40–250 A; Open-circuit voltage: 58 V; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Integrated; Insulation designation: F; Dimensions: 970×320×800 mm; Weight: 62 kg; Controls / configuration: Digital single/double-pulse; 2T/4T; inductance control; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit.; Electrical-input requirement: Confirm the actual input-current and supply-capacity schedule for the selected process and operating point 0314-07 | Gas-shielded 50–350 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 22.9 A; gas-shielded 21.2 A; Input capacity: MMA 15 kVA; gas-shielded 14 kVA; Output-current adjustment: MMA 20–350 A; gas-shielded 50–350 A; Open-circuit voltage: 60 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 1.0–1.2 mm; Insulation designation: F; Dimensions: 620×310×520 mm; Weight: 35.5 kg; Controls / configuration: Separate feeder; 2T/4T; crater current/voltage and gas-check settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-08 | Separate-feeder welding configuration Quotation fields: Current supply, process, output range, duty conditions, feeder and operating kit 0314-09 | MMA 20–450 A welder Supply: Three-phase 380 V; Input current: Gas-shielded 26 A; MMA 27.7 A; Input capacity: Gas-shielded 17.2 kVA; MMA 18.2 kVA; Output-current adjustment: Gas-shielded 50–450 A; MMA 20–450 A; Open-circuit voltage: 68 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 1.0–1.6 mm; Insulation designation: F; Dimensions: 565×285×485 mm 0314-10 | MMA 20–350 A welder Supply: Three-phase 380 V; Output-current adjustment: Gas-shielded 50–350 A; MMA 20–350 A; Open-circuit voltage: 60 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 565×285×485 mm; Electrical-input requirement: Confirm the actual input-current and supply-capacity schedule for the selected process and operating point 0314-11 | MMA 30–120 A welder Supply: Single-phase 220 V ±15%; Output-current adjustment: Gas-shielded 40–120 A; MMA 30–120 A; Open-circuit voltage: 57 V; Duty-cycle reference: 20%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.73; Wire feeder: Integrated; Wire diameter: 0.6 / 0.8 / 1.0 mm; Insulation designation: F; Dimensions: 420×200×330 mm; Weight: 9.2 kg; Electrical-input requirement: Confirm the actual input-current and supply-capacity schedule for the selected process and operating point 0314-12 | MMA 30–120 A welder Supply: Single-phase 220 V ±15%; Output-current adjustment: Gas-shielded 40–120 A; MMA 30–120 A; Open-circuit voltage: 53 V; Duty-cycle reference: 15%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.73; Wire feeder: Integrated; Wire diameter: 0.6 / 0.8 / 1.0 mm; Insulation designation: F; Dimensions: 310×135×215 mm; Weight: 5.6 kg; Electrical-input requirement: Confirm the actual input-current and supply-capacity schedule for the selected process and operating point 0314-13 | 30–100 A air-plasma cutter Supply: Three-phase 380 V ±15%; Input current: 23 A; Input capacity: 15.2 kVA; Output-current adjustment: 30–100 A; Open-circuit voltage: 300 V; Duty-cycle reference: 30%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Insulation designation: F; Dimensions: 690×320×680 mm; Weight: 66 kg 0314-14 | Gas-shielded 50–500 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 38.4 A; gas-shielded 37.5 A; Input capacity: MMA 25.3 kVA; gas-shielded 24.7 kVA; Output-current adjustment: MMA 20–500 A; gas-shielded 50–500 A; Open-circuit voltage: 68 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 1.0–1.6 mm; Insulation designation: F; Dimensions: 620×320×515 mm; Weight: 32 kg; Controls / configuration: IGBT inverter; separate feeder; feedback and inductance settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-15 | Gas-shielded 50–350 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 22.8 A; gas-shielded 21.2 A; Input capacity: MMA 15 kVA; gas-shielded 13.9 kVA; Output-current adjustment: MMA 20–350 A; gas-shielded 50–350 A; Open-circuit voltage: 60 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 620×320×515 mm; Weight: 30 kg; Controls / configuration: IGBT inverter; separate feeder; feedback and inductance settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-16 | Gas-shielded 50–250 A welder Supply: Three-phase 380 V ±15%; Input current: MMA 14.4 A; gas-shielded 12.7 A; Input capacity: MMA 9.5 kVA; gas-shielded 8.4 kVA; Output-current adjustment: MMA 20–250 A; gas-shielded 50–250 A; Open-circuit voltage: 50 V; Duty-cycle reference: 25%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Integrated; Wire diameter: 0.8–1.2 mm; Insulation designation: F; Dimensions: 520×280×445 mm; Weight: 25.2 kg; Controls / configuration: Integrated feeder; inductance, arc-start/burnback and slow feed; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-17 | 50–500 A pulse welder Supply: Three-phase 380 V ±15%; Input current: 37.5 A; Input capacity: 24.7 kVA; Output-current adjustment: 50–500 A; Open-circuit voltage: 67 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 1.0–1.6 mm; Insulation designation: F; Dimensions: 620×312×520 mm; Weight: 37.5 kg; Controls / configuration: Digital single/double-pulse; 2T/4T; inductance and crater settings; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-18 | Pulse gas-shielded welding configuration Quotation fields: Current supply, process, output range, duty conditions, feeder and operating kit 0314-19 | 50–500 A gas-shielded welder Supply: Three-phase 380 V ±15%; Input current: 41 A gas-shielded; Input capacity: 25 kVA gas-shielded; Output-current adjustment: 50–500 A gas-shielded; Open-circuit voltage: 67 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Wire feeder: Separate; Wire diameter: 1.0–1.2 mm; Insulation designation: F; Dimensions: 670×335×660 mm; Weight: 44 kg; Controls / configuration: Solid/flux-cored wire; joint/separate adjustment; 2T/4T; gas/wire checks; Package direction: Return lead, torch and regulator; separate feeder where specified. Confirm final kit. 0314-20 | 30–100 A air-plasma cutter Supply: Three-phase 380 V ±15%; Input current: 23 A; Input capacity: 15.2 kVA; Output-current adjustment: 30–100 A; Open-circuit voltage: 300 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Thickness reference: 25–35 mm; material and quality conditions to confirm; Insulation designation: F; Dimensions: 690×320×680 mm; Weight: 66 kg; Built-in air-pump power: 1500 W; Controls / configuration: Integrated air pump; 2T/4T; postflow; regulator with drain/gauge; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-21 | 40–160 A air-plasma cutter Supply: Three-phase 380 V ±15%; Input current: 46 A; Input capacity: 29 kVA; Output-current adjustment: 40–160 A; Open-circuit voltage: 390 V; Duty-cycle reference: 50%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Thickness reference: 35–60 mm; confirm workpiece and quality conditions; Insulation designation: F; Dimensions: 690×350×660 mm; Weight: 54.5 kg; Controls / configuration: Piercing/bevelling direction; arc-voltage sampling; postflow; 2T/4T; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-22 | 15–40 A air-plasma cutter Supply: 220 V ±15%; Input current: 28 A; Input capacity: 6.2 kVA; Output-current adjustment: 15–40 A; Open-circuit voltage: 270 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.73; Thickness reference: 8–12 mm; conditions to confirm; Insulation designation: F; Dimensions: 450×170×340 mm; Weight: 21.8 kg; Built-in air-pump power: 750 W; Controls / configuration: Integrated air pump; regulator/drain/gauge; high-frequency start; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-23 | 30–100 A air-plasma cutter Supply: Three-phase 380 V ±15%; Input current: 23 A; Input capacity: 15.2 kVA; Output-current adjustment: 30–100 A; Open-circuit voltage: 330 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Thickness reference: 25–35 mm; conditions to confirm; Insulation designation: F; Dimensions: 690×270×475 mm; Weight: 26 kg; Controls / configuration: External-air layout; 2T/4T; postflow; regulator/drain/gauge; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-24 | 30–80 A air-plasma cutter Supply: Three-phase 380 V ±15%; Input current: 17.2 A; Input capacity: 11.3 kVA; Output-current adjustment: 30–80 A; Open-circuit voltage: 330 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.93; Thickness reference: 25–30 mm; conditions to confirm; Insulation designation: F; Dimensions: 630×270×455 mm; Weight: 22 kg; Controls / configuration: External-air layout; 2T/4T; postflow; regulator/drain/gauge; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-25 | 15–40 A air-plasma cutter Supply: 220 V ±15%; Input current: 28 A; Input capacity: 6.2 kVA; Output-current adjustment: 15–40 A; Open-circuit voltage: 270 V; Duty-cycle reference: 60%; conditions to confirm; Efficiency reference: 85%; Power factor: 0.73; Thickness reference: 8–12 mm; conditions to confirm; Insulation designation: F; Dimensions: 450×180×310 mm; Weight: 10.2 kg; Controls / configuration: External-air layout; postflow; regulator/drain/gauge; Package direction: Return lead and cutting torch; confirm air-treatment and consumables. 0314-26 | Motor-coupled side-channel blower configuration Layout: Finned blower housing, motor and mounting arrangement; Quotation fields: Flow at pressure/vacuum, motor rating, frequency, ports, dimensions and operating temperature 0314-27 | Cordless drill-driver Layout: Adjustable chuck/clutch ring; grip-integrated battery layout; Quotation fields: Voltage, pack, charger, chuck, torque, speeds and materials 0314-28 | Manual arc-welding product directions Listed constructions: Standard inverter, dual-module, dual-voltage and wide-input directions; Listed wide-input reference: 140–560 V; confirm current configuration and output at each input 0314-29 | Argon-arc welding enquiries Product direction: TIG / argon-arc equipment; Quotation fields: DC or AC/DC requirement, current, pulse, start method, torch cooling and duty 0314-30 | Additional plasma-cutter constructions Listed directions: Module, single-device, dual-voltage and compact configurations; Quotation fields: Actual input, output, air system, CNC interface and cutting requirements 0314-31 | Single- and two-stage blower family enquiries Catalogue directions: Single-stage and two-stage side-channel blower families; alternative blower layouts; Quotation fields: Actual operating point, selected stage arrangement, supply and process gas 0314-32 | Blower-system accessories Project scope: Air-system accessory matching; Quotation fields: Filters, pressure/vacuum protection, connection, silencing and installation needs 0314-33 | Cordless and portable tool projects Named tool directions: Reciprocating saw, two-speed drill, driver, oscillating tool, circular saw, work light, sander and jigsaw; Quotation fields: Actual voltage, pack, charger, capacities, attachments and kit 0314-34 | Grinding and air-compressor enquiries Product directions: Angle-grinding and air-compressor families; Quotation fields: Grinder disc/spindle/speed; compressor delivered air, pressure, duty, tank and supply 0314-35 | Heating and cooling fan projects Catalogue scope: Fan and heater configurations; Quotation fields: Supply, airflow, heating capacity, temperature control, mounting and environment 0314-36 | Deep-groove and tapered-roller bearings Families: Deep-groove ball bearings; tapered-roller bearings; Quotation fields: Bore, outside diameter, width, load, speed, fit, clearance, material and lubrication 0314-37 | Application-specific bearing requirements Directions: High-speed, moisture-exposure and low-noise designs; axial-load and pump service; Application areas: Motors, power/pneumatic tools, oil-free compressors, textiles, chainsaws, oil pumps, sewing machines, reducers, water pumps, fans and automotive; Quotation fields: Actual load/speed cycle, sealing, precision, lubrication and endurance test 0314-38 | Welding cables and electrical connections Scope: Wires/cables and welding connection requirements; Quotation fields: Conductor, cross-section, insulation, length, current/duty, termination and environment 0314-39 | Welding accessories and cooling Scope: Welding parts, helmet and water-cooling directions; Quotation fields: Torch/consumable interface, current/duty, cooling capacity, filter/shade and protective documentation 0314-40 | Motors, pumps and mechanical project support Directions: Motor, pump/vacuum, gas-compression and sheet-metal processing enquiries; Quotation fields: Duty, fluid or gas, operating point, materials, interfaces and drawings 0314-41 | Single-phase MIG / MMA configuration Supply: Single-phase AC 220 V ±15%; 50/60 Hz; Input current: 25.8 A; Listed power capacity: 5.7 kVA; Output-current range: MIG 50–160 A; MMA 20–150 A; Electrode: 1.6–4.0 mm; Wire: 0.8–1.0 mm; Open-circuit voltage: 57 V; Duty-cycle reference: 60% at 40°C; current basis to confirm; Dimensions / machine weight: 400×200×335 mm / 9.35 kg 0314-42 | Single-phase MIG / MMA configuration Supply: Single-phase AC 220 V ±15%; 50/60 Hz; Input current: 35.2 A; Listed power capacity: 7.7 kVA; Output-current range: MIG 50–200 A; MMA 20–180 A; Electrode: 1.6–5.0 mm; Wire: 0.8–1.0 mm; Open-circuit voltage: 59 V; Duty-cycle reference: 60% at 40°C; current basis to confirm; Dimensions / machine weight: 400×200×335 mm / 9.35 kg This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.