FACTORY SOURCING HUB — WATER PUMPS, SOLAR PUMPING & GARDEN EQUIPMENT SOURCING Page reference: 0323 Send to: kunhuow@gmail.com Reply email: Product / reference: Quantity per model and variation: Sales market / intended user: Material / size / performance: Logo / artwork: Packaging / labels / carton requirements: Samples / testing / documents: Target budget / timing / shipping basis: Additional requirements: REFERENCE OPTIONS 0323-01 | Submersible peripheral pump Voltage V/Hz: 220-240 (frequency not stated in this field); Power kW: 0.37; Maximum flow m³/h: 2.2; Maximum head m: 35; Outlet: 1"; Configuration order — same ratings: 1: Same numerical ratings; control assembly differs; 2: Same numerical ratings; control assembly differs; Limits: Clean water; immersion ≤3.5m; F/IPX8; optional float control; Construction: Plastic support/body components; brass impeller 0323-02 | Automatic self-priming peripheral pump Voltage for 50Hz V: 180-220 / 220-240; Voltage for 60Hz V: 220-240; Power kW | Q m³/h → H m (same curve point): 0.13 | 0.9→12; 0.25 | 1.2→15; 0.37 | 1.2→20; 0.6 | 1.5→20; 0.75 | 1.5→28 0323-03 | Compact peripheral transfer pump Power kW | Q m³/h → H m (same curve point): 0.37 | 1.2→15; 0.75 | 1.5→30 0323-04 | Self-priming peripheral pump with revised housing Power kW | Q m³/h → H m (same curve point): 0.125 | 1.2→10; 0.35 | 1.5→15; 0.55 | 1.5→20; 0.75 | 1.8→25 0323-05 | Domestic self-priming peripheral pump Power kW | Q m³/h → H m (same curve point): 0.125 | 1.2→12; 0.35 | 1.5→16; 0.55 | 1.5→20.5 0323-06 | Self-priming peripheral pump with alternate assembly Voltage for 50Hz V: 180-220 / 220-240; Voltage for 60Hz V: 110 / 220-240; Power kW | Q m³/h → H m (same curve point): 0.13 | 1.2→7.5; 0.25 | 1.2→11.5; 0.37 | 1.5→13.5; 0.55 | 1.5→22; 0.75 | 1.8→25.5 0323-07 | Small peripheral pump for domestic supply Power kW: 0.11; Configuration order — Q m³/h → H m (same curve point): 1: 0.9→11 0323-08 | Peripheral pump for small water systems Power kW: 0.125; Configuration order — Q m³/h → H m (same curve point): 1: 0.9→11 0323-09 | Peripheral pump for water transfer Power kW | Q m³/h → H m (same curve point): 0.37 | 1.5→15; 0.6 | 1.5→30; 0.75 | 1.5→35 0323-10 | Peripheral pump power ladder Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.3 | 1.2→12; 1φ | 0.37 | 1.2→20; 1φ | 0.6 | 1.5→30; 1φ | 0.75 | 1.5→35; 1φ | 0.9 | 1.2→35; 1φ | 1.1 | 1.8→50; 3φ | 1.1 | 1.8→50; 1φ | 1.5 | 2.1→55; 3φ | 1.5 | 2.1→55; 1φ | 2.2 | 2.1→65; 3φ | 2.2 | 2.1→65 0323-11 | Self-priming peripheral pump ladder Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.37 | 1.2→18; 1φ | 0.6 | 1.5→18; 1φ | 0.75 | 1.5→28; 1φ | 1.1 | 2.1→30; 3φ | 1.1 | 2.1→30 0323-12 | Domestic self-priming peripheral range Voltage for 50Hz V: 180-220 / 220-240; Voltage for 60Hz V: 110 / 220-240; Power kW | Q m³/h → H m (same curve point): 0.13 | 1.2→7.5; 0.25 | 1.2→11.5; 0.37 | 1.5→13.5; 0.55 | 1.5→22; 0.75 | 1.8→25.5 0323-13 | Cast-iron jet pump Power kW | Q m³/h → H m (same curve point): 0.3 | 1.2→20; 0.45 | 1.2→25; 0.6 | 1.5→28.5; 0.75 | 2.1→29; 0.75 | 1.5→34.5; 0.9 | 2.1→36; 0.9 | 1.5→43 0323-14 | Stainless-steel jet pump Power kW | Q m³/h → H m (same curve point): 0.3 | 1.5→16.5; 0.45 | 1.5→22; 0.6 | 1.5→25; 0.75 | 1.8→30; 0.9 | 2.1→32 0323-15 | Deep-well jet pump and ejector combinations Power kW | HS m | Q m³/h → H m (same curve point): 0.55 | 15 | 0.72→21; 0.75 | 15 | 0.84→27; 1.1 | 15 | 0.84→44; 0.55 | 20 | 0.48→19; 0.75 | 20 | 0.6→24; 1.1 | 20 | 0.84→38; 0.55 | 25 | 0.36→14; 0.75 | 25 | 0.48→20; 1.1 | 25 | 0.6→36; 0.55 | 30 | 0.12→13; 0.75 | 30 | 0.24→19; 1.1 | 30 | 0.48→32; 0.75 | 35 | 0.12→15; 1.1 | 35 | 0.24→31; 1.1 | 40 | 0.12→28 0323-16 | Single-stage centrifugal water pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.25 | 3→13.5; 1φ | 0.37 | 3→18; 1φ | 0.5 | 3→22.5; 3φ | 0.5 | 3→22.5; 1φ | 0.75 | 3.6→29; 3φ | 0.75 | 3.6→29; 1φ | 1.1 | 3.6→35; 3φ | 1.1 | 3.6→35; 1φ | 1.5 | 3.6→42.5; 3φ | 1.5 | 3.6→42.5; 3φ | 2.2 | 3.6→50.5; 1φ | 1.1 | 3.6→33; 3φ | 1.1 | 3.6→33; 1φ | 1.5 | 3.6→35.4; 3φ | 1.5 | 3.6→35.4 0323-17 | Multistage centrifugal water pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.45 | 1.8→26.5; 1φ | 0.6 | 1.8→36; 1φ | 0.6 | 2.4→30.5; 1φ | 0.75 | 2.4→38; 3φ | 0.75 | 2.4→38 0323-18 | Stainless-steel multistage centrifugal pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.37 | 3.6→15; 1φ | 0.6 | 3→24; 3φ | 0.6 | 3→24; 1φ | 0.75 | 3→30; 3φ | 0.75 | 3→30; 1φ | 0.9 | 3.6→35; 3φ | 0.9 | 3.6→35 0323-19 | DC solar centrifugal surface pump W | motor V | input V | Qmax m³/h | Hmax m | PV Voc < V: 550 | 48 | 60–90 | 6 | 24 | 100; 750 | 72 | 90–120 | 21 | 14 | 150; 1100 | 72 | 90–120 | 26 | 15 | 150; 1500 | 110 | 110–150 | 45 | 17 | 200; Controller: MPPT; IP55 controller; ambient −15 to +60°C; soft start; float control; Array: Recommended PV power ≥1.3×pump power; Qmax/Hmax are separate endpoints 0323-20 | Self-priming stainless multistage pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.6 | 3→24; 3φ | 0.6 | 3→24; 1φ | 0.75 | 3→30; 3φ | 0.75 | 3→30; 1φ | 0.9 | 3.6→35; 3φ | 0.9 | 3.6→35 0323-21 | DC solar peripheral surface pump W | motor V | input V | Qmax m³/h | Hmax m | PV Voc < V: 210 | 24 | 30–48 | 2 | 25 | 50; 280 | 24 | 30–48 | 2 | 30 | 50; 550 | 48 | 60–90 | 3 | 50 | 100; 750 | 72 | 90–120 | 3 | 65 | 150; Controller: MPPT; controller IP55; ambient −15 to +60°C; Array: PV power ≥1.3×pump power; separate Qmax/Hmax endpoints 0323-22 | Hybrid AC/DC solar centrifugal pump W | AC V | DC V | Qmax m³/h | Hmax m | PV Voc < V: 750 | 80–280 | 90–200 | 21 | 14 | 430; 1100 | 80–280 | 90–300 | 26 | 15 | 430; 1500 | 80–280 | 90–380 | 45 | 17 | 430; Controller: MPPT AC/DC; controller IP55; ambient −15 to +60°C; Array: PV power ≥1.3×pump power; separate Qmax/Hmax endpoints 0323-23 | Semi-open stainless centrifugal pump kW | Q m³/h | H m | passage mm: 0.37 | 6 | 7.5 | 9; 0.75 | 12 | 7 | 12; 0.9 | 12 | 10 | 12; 1.1 | 24 | 6.7 | 12; 1.5 | 24 | 10 | 16; 2.2 | 24 | 12.7 | 16; 3 | 24 | 15.2 | 19; Construction: AISI304 body/impeller/bracket cover; SiC/Carbon mechanical seal; Phases: Both phases through 2.2kW; 3kW listed as three-phase only 0323-24 | Plastic dirty-water submersible pump W | Hmax m | Qmax m³/h | immersion m | particles mm: 250 | 5 | 8 | 7 | 25; 400 | 5 | 10 | 7 | 25; 550 | 7 | 12 | 7 | 35; 750 | 8 | 14 | 7 | 35; Limits: Immersion ≤7m; liquid ≤35°C; IPX8; float; 10m cable; Packing: 4pcs/carton; 440×350×330mm or 420×350×370mm by variant 0323-25 | Stainless single-stage centrifugal pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.37 | 3.6→15.7; 3φ | 0.37 | 3.6→15.7; 1φ | 0.55 | 3.6→23.4; 3φ | 0.55 | 3.6→23.4; 1φ | 0.75 | 3.6→26; 3φ | 0.75 | 3.6→26; 1φ | 0.55 | 7.2→13.3; 3φ | 0.55 | 7.2→13.3; 1φ | 1.1 | 7.2→21.2; 3φ | 1.1 | 7.2→21.2; 1φ | 0.75 | 10.8→14.2; 3φ | 0.75 | 10.8→14.2; 1φ | 1.1 | 10.8→17.5; 3φ | 1.1 | 10.8→17.5; 1φ | 1.5 | 10.8→22.4; 3φ | 1.5 | 10.8→22.4; 1φ | 2.2 | 10.8→25.7; 3φ | 2.2 | 10.8→25.7; 1φ | 1.1 | 15→13.5; 3φ | 1.1 | 15→13.5; 1φ | 1.5 | 18→16.3; 3φ | 1.5 | 18→16.3; 1φ | 2.2 | 18→20; 3φ | 2.2 | 18→20; Limits: Liquid ≤85°C; ambient ≤40°C; operating pressure ≤4.5bar; altitude ≤1000m; F/IPX4; Materials: AISI304 wet components; Graphite/SiC seal 0323-26 | Hybrid AC/DC solar peripheral pump Configuration: 750W; AC80–280V; DC90–200V; Qmax3m³/h; Hmax65m; PV Voc<430V; Connections: 1×1inch; 2m cable; PV power ≥1.3×pump power; independent endpoints 0323-27 | Plastic clean-water submersible pump W | Hmax m | Qmax m³/h: 250 | 6 | 7; 400 | 6 | 9; Limits: 7m immersion; 5mm particles; 35°C; IPX8; float; 10m cable; Packing: 4pcs/carton; 440×350×300mm 0323-28 | Stainless-housing garden drainage pump W | Hmax m | Qmax m³/h: 550 | 7 | 13.5; 750 | 8 | 16.5; 1000 | 9 | 19.5; Limits: 7m immersion; 35mm particles; 35°C; IPX8; float; 10m cable; Packing: 4pcs/carton; 440×350×410mm 0323-29 | Adaptive heating circulator Qmax m³/h | Hmax m | W: 2 | 4.1 | 22; 2.3 | 5.2 | 32; 2.6 | 6.2 | 45; 2 | 4 | 22; 2.3 | 5.1 | 32; 2.6 | 6.1 | 45; 2.1 | 4 | 22; 2 | 4 | 22; 2.3 | 5 | 32; 2.3 | 5 | 32; 2.4 | 6.1 | 45; 2.7 | 6 | 45; 2.2 | 4 | 22; 2.5 | 5.1 | 32; 2.8 | 6.1 | 45; Electrical: 220–240V50Hz; Controls: Adaptation, proportional/constant pressure, three fixed speeds; night setback conditional 0323-30 | Automatic self-priming domestic booster Power kW | Q m³/h → H m (same curve point): 0.25 | 1.2→10; 0.37 | 1.2→15; 0.6 | 1.5→18; 0.75 | 1.5→25 0323-31 | Building pressure booster system 0323-32 | Wall-mounted gas-boiler circulation assemblies W at speeds 3/2/1 | Qmax L/min at speeds 3/2/1 | Hmax m at speeds 3/2/1: 100/85/70 | 37/28/17 | 6/5.2/3.4; 130/120/105 | 35/32/23 | 6.8/6.3/5.1; 100/85/70 | 35/33/27 | 5.9/5.7/5.3; 130/120/105 | 40/30/17 | 6.7/6/4.2; 100/85/70 | 38/28/17 | 5.8/4.8/3.2; 100/85/70 | 37/28/17 | 5.8/4.8/3.2; 130/120/105 | 42/35/23 | 6.5/5.6/4.8; 100/85/70 | 37/33/27 | 6/5.8/5.5; 130/120/105 | 43/35/22 | 6.9/6/4.3; 100/85/70 | 38/32/20 | 5.9/5.1/3.4; 130/120/105 | 42/35/27 | 6.8/6.2/5.1; Electrical: 230V50Hz; Qmax and Hmax independent at each speed 0323-33 | Borehole water pump with paired phase options kW | H m at Q 3m³/h: 0.55 | 30; 0.75 | 41; 0.92 | 51; 1.1 | 61; 1.3 | 71; 1.5 | 81; Electrical: Single-phase220–240V / three-phase380–415V; approximately2850rpm 0323-34 | Alternative borehole water pump kW | H m at Q 1.5m³/h: 0.75 | 28; 1.1 | 48; 1.5 | 56; Electrical: Single-phase220–240V / three-phase380–415V; approximately2850rpm 0323-35 | Vertical multistage pressure pump 0323-36 | Intelligent stainless horizontal multistage pump kW | H m at Q 2m³/h: 0.25 | 13.5; 0.37 | 20.5; 0.37 | 27.5; 0.55 | 33.5; 0.75 | 41.5; kW | H m at Q 3m³/h: 0.25 | 13; 0.37 | 19; 0.55 | 25.5; 0.55 | 32; 0.75 | 39; kW | H m at Q 4m³/h: 0.37 | 13; 0.55 | 20; 0.75 | 28; 0.75 | 35 0323-37 | Stainless horizontal multistage supply pump 0323-38 | Self-priming tank booster in three assemblies W | Hmax m | Qmax m³/h | suction m | stop bar: 600 | 35 | 3 | 7 | 2.4; 800 | 40 | 3.7 | 7 | 2.8; 1000 | 45 | 4.5 | 8 | 2.8; 1200 | 50 | 5 | 8 | 2.8; 600 | 35 | 3 | 7 | 2.4; 800 | 40 | 3.7 | 7 | 2.8; 1000 | 45 | 4.5 | 8 | 2.8; 1200 | 50 | 5 | 8 | 2.8; 600 | 35 | 3 | 7 | 2.4; 800 | 40 | 3.7 | 7 | 2.8; 1000 | 45 | 4.5 | 8 | 2.8; 1200 | 50 | 5 | 8 | 2.8; Assembly: Three assembly variants for each duty row; 19L tank; 1.4bar start; Limits: 35°C liquid; IPX4; 1.5m cable; Qmax/Hmax separate 0323-39 | Garden jet pump for 60 Hz supply W | Hmax m | Qmax m³/h | suction m: 600 | 35 | 3 | 7; 800 | 40 | 3.7 | 7; 1000 | 45 | 4.5 | 8; 1200 | 50 | 5 | 8; Limits: 60Hz range; 35°C liquid; IPX4; 1.5m cable; Qmax/Hmax separate 0323-40 | Horizontal multistage pump for building systems 0323-41 | Alternate stainless horizontal multistage range 0323-42 | Single-stage double-suction process pump 0323-43 | Vertical can-type condensate pump Conditions: Medium ≤80°C; 120°C only as special project requirement; counterclockwise viewed from drive end 0323-44 | Vertical long-shaft pump 0323-45 | Axial-flow chemical circulation pump 0323-46 | Vertical guide-vane mixed-flow pump Series envelope: Q0.61–16.7m³/s; H5–15m; 75–6000kW; calibre1500–3500mm; different configurations 0323-47 | Between-bearing petrochemical process pump 0323-48 | Vertical mixed-flow project pump 0323-49 | Hydraulic energy-recovery turbine 0323-50 | Submersible slurry pump kW | outlet mm | Qmax m³/h | Hmax m | particles mm: 4 | 80 | 99 | 14.8 | 30; 6 | 100 | 144 | 16.9 | 30; 9 | 150 | 192 | 21.5 | 30; Endpoints: Qmax/Hmax independent; 30mm solids per listed configuration 0323-51 | Submersible dewatering pump kW | outlet mm | Qmax m³/h | Hmax m | particles mm: 1.5 | 50 | 33 | 22 | 8.5; 2.2 | 50 | 33 | 26 | 8.5; 3.7 | 50 | 33 | 34 | 8.5; 1.5 | 80 | 40 | 14.5 | 8.5; 2.2 | 80 | 55 | 19 | 8.5; 3.7 | 80 | 55 | 29 | 8.5; 5.5 | 80 | 75 | 34 | 8.5; 3.7 | 100 | 90 | 18.5 | 8.5; 5.5 | 100 | 105 | 23 | 8.5; Endpoints: Qmax/Hmax independent; 8.5mm solids per listed configuration 0323-52 | Whirlpool and hydromassage circulation pump kW | V at 50 Hz | V at 60 Hz | Qmax L/min | Hmax m: 0.5 | 220–240 | 220 | 300 | 8; 0.6 | 220–240 | 110 | 320 | 9; 0.8 | 220–240 | 110 | 330 | 10; 0.9 | 220–240 | 110 | 350 | 11; 1.1 | 220–240 | 110 | 400 | 11; 1.3 | 220–240 | 110 | 450 | 12; Conditions: Liquid ≤50°C; plastic body; thermal protector; 50mm standard / 32mm optional ports; separate endpoints 0323-53 | Vertical guide-vane volute pump Conditions: Liquid <55°C; single/double foundation; counterclockwise from motor, clockwise design on request 0323-54 | Compact submersible sewage pump Voltage/Frequency V/Hz: 180-220/50; Power kW | Rated Flow m³/h | Rated Head m | Max. Flow m³/h | Max. Head m | Max. dia. of particle mm: 0.18 | 6 | 5 | 11 | 8 | 20; 0.25 | 8 | 5 | 12 | 9 | 20; 0.37 | 8 | 6 | 13 | 11 | 20; 0.55 | 10 | 8 | 16 | 13.5 | 20; 0.75 | 10 | 11 | 19 | 17 | 20; 1.1 | 15 | 10 | 26 | 13.5 | 25; 1.5 | 18 | 12 | 32 | 19 | 25; 2.2 | 20 | 15 | 34.5 | 23 | 25; Conditions: Liquid ≤40°C; immersion ≤5m; F/IPX8; rated Q/H paired, maximum endpoints independent 0323-55 | Automatic submersible pressure pump W | Hmax m | Qmax m³/h | impellers: 900 | 35 | 6 | 3; 1100 | 45 | 6 | 4; 900 | 35 | 6 | 3; 1100 | 45 | 6 | 4; Limits: Immersion ≤12m; 1mm particles; liquid ≤35°C; IPX8; 15m cable; Packing: 1pc/carton; 260×215×540mm or 260×215×565mm 0323-56 | Battery-powered submersible transfer pump Configuration: 200W; 18V5Ah battery; Qmax5.5m³/h; Hmax10m; immersion2m; outlet25mm; Packing: 230×145×245mm; gross3.2kg; battery housing stays appropriately protected 0323-57 | Petrol-driven cast-iron centrifugal pump Configuration: 6.5HP/196cc; fuel3.1L; oil0.55L; exact Q15m³/h→H40m; Packing: 470×433×450mm; gross30kg 0323-58 | Compact petrol water pumps HP | cc | Q m³/h | H m: 1.6 | 42.7 | 4 | 26.9; 1.6 | 42.7 | 10 | 27.5 0323-59 | End-suction building and process water pump 0323-60 | Intelligent deep-well pressure pump W | Hmax m | Qmax m³/h | immersion m | stages | start bar: 750 | 35 | 6 | 12 | 5 | 2; 900 | 42 | 6 | 16 | 6 | 2.5; 1000 | 49 | 6 | 19 | 7 | 2.5; 1100 | 55 | 6 | 19 | 8 | 3; 750 | 35 | 6 | 19 | 5 | —; 900 | 42 | 6 | 19 | 6 | —; 1000 | 49 | 6 | 19 | 7 | —; 1100 | 55 | 6 | 19 | 8 | —; 1200 | 63 | 6 | 19 | 9 | —; 1300 | 70 | 6 | 19 | 10 | —; Limits: Qmax/Hmax separate; 35°C; IPX8; 22m cable/rope; immersion varies by row 0323-61 | High-pressure deep-well submersible pump V options | Q m³/h | H m: 110–120|220–240 | 4 | 23.4; 110–120|220–240 | 4 | 30.5; 110–120|220–240 | 4 | 38.7; 110–120|220–240 | 4 | 46.9; Construction: Minimum well4inch; AISI304 outer housing; polymer hydraulic parts; exact Q/H paired 0323-62 | DC solar borehole pump with stainless impeller W | rated V | input V | Qmax m³/h | Hmax m | PV Voc < V: 300 | 24 | 30–48 | 4 | 35 | 50; 400 | 48 | 60–90 | 4 | 50 | 100; 500 | 48 | 60–90 | 4 | 67 | 100; 600 | 48 | 60–90 | 4 | 80 | 100; 750 | 72 | 90–120 | 4.8 | 95 | 150; 1100 | 72 | 90–120 | 4.8 | 112 | 150; 1100 | 110 | 110–150 | 4.8 | 112 | 200; 1500 | 110 | 110–150 | 4.8 | 135 | 200; 1500 | 110 | 110–150 | 4.6 | 150 | 200; 1500 | 110 | 110–150 | 4.3 | 165 | 200; Array: PV power ≥1.3×pump power; 1¼inch outlet; 2m cable; maxima independent 0323-63 | Diesel-driven water pump HP | cc | Q m³/h | H m: 3.8 | 219 | 20 | 13; 3.8 | 219 | 30 | 15 0323-64 | DC solar borehole pump with plastic impeller 0323-65 | DC solar screw pump W | rated V | input V | Qmax m³/h | Hmax m | PV Voc < V: 80 | 12 | 20–36 | 0.5 | 28 | 50; 120 | 24 | 30–48 | 1.2 | 56 | 50; 210 | 36 | 30–48 | 1.2 | 77 | 50; 500 | 48 | 60–90 | 1.7 | 109 | 100; 750 | 48 | 60–90 | 2 | 150 | 100; 750 | 72 | 90–120 | 2 | 150 | 150; 1100 | 72 | 90–120 | 2.2 | 180 | 150; Array: PV power ≥1.3×pump power; ¾inch outlet; 2m cable; maxima independent 0323-66 | Rain-barrel transfer pump Configuration: 300W; Qmax2.2m³/h; Hmax11m; immersion7m; particles1mm; 35°C; IPX8; Packing: 4pcs/carton; 390×390×450mm; gross20.9kg 0323-67 | High-head petrol water pump HP | cc | Q m³/h | H m: 6.5 | 196 | 15 | 44.5; 6.5 | 196 | 15 | 44.5; 6.5 | 196 | 15 | 45; 6.5 | 196 | 15 | 45; 6.5 | 208 | 15 | 41; 6.5 | 208 | 15 | 45 0323-68 | Petrol cast-iron water-pump assemblies HP | cc | Q m³/h | H m: 6.5 | 196 | 20 | 16; 6.5 | 196 | 30 | 19.5 0323-69 | Stainless vertical multistage water systems 0323-70 | Spa circulation pump for 60 Hz systems kW | Qmax L/min | Hmax m: 0.6 | 320 | 9; 0.8 | 330 | 10; 0.9 | 350 | 11; 1.1 | 400 | 11; 1.3 | 450 | 12; Connections: 60Hz range; 50mm standard /32mm optional; Qmax/Hmax independent 0323-71 | Domestic booster for solar-heated water systems Configuration: Single-phase230V50Hz; 120W; Qmax25L/min; Hmax9m; Packing: 198×143×160mm; net2.72kg/gross2.74kg; independent endpoints 0323-72 | Multi-speed hot-water booster W at speeds 3/2/1 | Qmax L/min at speeds 3/2/1 | Hmax m at speeds 3/2/1: 74/54/34 | 38.3/30/21.7 | 4.2/3.6/2.4; 85/60/40 | 38.3/30/21.7 | 4.5/4/2.6; 96/69/45 | 38.3/28.3/21.7 | 5.5/4.7/3; 270/200/160 | 58.3/45/25 | 12/11/3.5; Electrical: 220–240V50Hz; speed order3/2/1; independent endpoints 0323-73 | Heating circulation pump ladder speed 3 W | speed 3 Qmax L/min | speed 3 Hmax m: 67 | 46 | 4.5; 67 | 46 | 4.5; 68 | 51 | 4.3; 72 | 60 | 4.6; 73 | 64 | 4.6; 69 | 60 | 4.3; 85 | 40 | 4.5; 85 | 47 | 4.5; 75 | 50 | 5.2; 73 | 60 | 5.3; 75 | 63 | 5.2; 73 | 63 | 5.2; 85 | 48 | 6; 85 | 48 | 6; 96 | 53 | 5.5; 83 | 58 | 5.5; 83 | 68 | 6.1; 85 | 66 | 5.9; 150 | 67 | 6.3; 150 | 67 | 6.3; 150 | 67 | 6.3; 200 | 120 | 7.1; 270 | 167 | 7.3; 270 | 170 | 7.3; 270 | 170 | 7.3; 270 | 170 | 7.3; 268 | 81 | 12; 268 | 81 | 12; Electrical: 220–240V50Hz; speed3 reference; separate Qmax/Hmax at that speed 0323-74 | Hybrid solar borehole pump with plastic impeller W | AC V | DC V | Qmax m³/h | Hmax m: 750 | 80–280 | 90–200 | 3.5 | 95; 1100 | 80–280 | 90–300 | 3.8 | 123; 1300 | 80–280 | 90–300 | 3.8 | 155; 1500 | 80–280 | 90–380 | 3.8 | 180; 1500 | 80–280 | 90–380 | 3.5 | 195; Array: PV Voc<430V; PV power ≥1.3×pump; 1¼inch; 2m cable; endpoints independent 0323-75 | Hybrid solar borehole pump with stainless impeller W | AC V | DC V | Qmax m³/h | Hmax m: 750 | 80–280 | 90–200 | 4.8 | 95; 1100 | 80–280 | 90–300 | 4.8 | 112; 1500 | 80–280 | 90–380 | 4.8 | 135; 1500 | 80–280 | 90–380 | 4.6 | 150; 1500 | 80–280 | 90–380 | 4.3 | 165; Array: PV Voc<430V; PV power ≥1.3×pump; 1¼inch; 2m cable; endpoints independent 0323-76 | Vertical in-line circulation pump 0323-77 | Small hot-water booster kW | Q m³/h | H m: 0.125 | 4.5 | 3.8; 0.25 | 6 | 4.6; 0.37 | 9 | 6.2; 0.55 | 9 | 14.9; 0.37 | 2.4 | 13.4; 0.75 | 3 | 26.3 0323-78 | Hot-water and industrial circulation booster kW | Q m³/h | H m: 1.5 | 18 | 19; 2.2 | 18 | 26 0323-79 | Multistage submersible pressure pump W | Hmax m | Qmax m³/h | impellers: 900 | 32 | 7 | 3; 1100 | 42 | 7 | 4; 1300 | 52 | 7 | 5; Limits: Immersion7m; particles1mm; 35°C; IPX8; 10m cable; float; Packing: 1pc/carton; 480×250×210/502×250×210/527×250×210mm by configuration 0323-80 | Petrol sewage-transfer pump Configuration: 6.5HP;196cc;fuel3.1L;oil0.55L; Q30m³/h→H18.5m; solids<22mm 0323-81 | Petrol trash-pump configurations HP | cc | Q m³/h | H m: 5 | 163 | 20 | 18.6; 9 | 270 | 30 | 16 0323-82 | Battery lawnmowers with brushless motors width cm | motor W | height mm | bag L | drive: 40 | 600 | 30–80 | 45 | push; 46 | 800 | 30–80 | 70 | push; 46 | 800 | 30–80 | 70 | self-propelled; 48 | 1000 | 30–80 | 70 | push; 48 | 1000 | 30–80 | 70 | self-propelled; 51 | 1000 | 30–80 | 70 | push; 51 | 1000 | 30–80 | 70 | self-propelled; Construction: Metal deck; rear discharge; six central height settings; 7/8inch front/rear wheels 0323-83 | Domestic water-system pump W | Hmax m | Qmax m³/h: 900 | 42 | 3.6; 1100 | 46 | 4.6; 900 | 42 | 3.6; 1100 | 46 | 4.6; 900 | 42 | 3.6; 1100 | 46 | 4.6; Limits: 8m suction;35°C;IPX4;1.5m cable;1×1inch; maxima independent; Packing: 515×256×340mm; controls and gross weight vary by assembly 0323-84 | Tank-mounted domestic pressure booster W | Hmax m | Qmax m³/h: 900 | 42 | 3.6; 1100 | 46 | 4.6; Controls: 24L tank; start1.4bar/stop2.8bar; suction8m;35°C;IPX4; Packing: 550×340×695mm; maxima independent 0323-85 | Axially split horizontal multistage process pump 0323-86 | Permanent-magnet intelligent pressure booster 0323-87 | Overhung petrochemical processing pump 0323-88 | Petrol lawnmowers with push or powered drive width cm | cc | HP | bag L | drive: 46 | 149 | 4.5 | 70 | push; 46 | 149 | 4.5 | 70 | self-propelled; 51 | 171 | 5.5 | 70 | push; 51 | 171 | 5.5 | 70 | self-propelled; 48 | 171 | 5.5 | 70 | push; 48 | 171 | 5.5 | 70 | self-propelled; width cm | cc | HP | electric-start battery: 46 | 149 | 4.5 | lead-acid; 46 | 149 | 4.5 | lithium-ion; 51 | 171 | 5.5 | lead-acid; 51 | 171 | 5.5 | lithium-ion; 48 | 171 | 5.5 | lead-acid; 48 | 171 | 5.5 | lithium-ion; 56 | 196 | 6.5 | lead-acid; 56 | 196 | 6.5 | lithium-ion; width cm | cc | HP | drive: 56 | 196 | 6.5 | push; 56 | 196 | 6.5 | self-propelled; Shared construction: 30–80mm, six central heights;70L bag; steel deck;8/11inch wheels; mulch/rear/side discharge 0323-89 | Petrol lawnmowers with variable powered travel width cm | cc | HP | start: 46 | 149 | 4.5 | pull; 46 | 149 | 4.5 | electric/pull lithium; 48 | 171 | 5.5 | pull; 48 | 171 | 5.5 | electric/pull lithium; 51 | 171 | 5.5 | pull; 51 | 171 | 5.5 | electric/pull lithium; 56 | 196 | 6.5 | pull; 56 | 196 | 6.5 | electric/pull lithium; Shared construction: Travel2.5–4.3km/h;30–80mm,six heights;70L;8/11inch wheels;mulch/rear/side 0323-90 | Petrol tillers and guarded variants width cm | cc | HP | depth mm | blades | assembly: 36 | 132 | 4 | 200 | 4 | standard; 36 | 132 | 4 | 200 | 4 | protection discs; 45 | 79 | 3 | 200 | 4 | standard; 45 | 79 | 3 | 200 | 4 | protection discs and engine cover; 56 | 149 | 4.5 | 200 | 6 | standard; 56 | 149 | 4.5 | 200 | 6 | protection discs; Common: 200mm depth;260mm blades;one forward;fuel0.6L/oil0.4L; reference conditions 0323-91 | Submersible axial-flow project pump Series envelope: Q550–45000m³/h;H2–20m;calibre350–1600mm; different configurations 0323-92 | Rural-well and irrigation submersible pump Q m³/h | H m: 3 | 11; 3 | 15; 3 | 22.5; 3 | 29.5; 3 | 11; 3 | 14; 3 | 18; 10 | 10; 10 | 16; 10 | 16; 10 | 18; 15 | 7; 15 | 10; 15 | 14; 15 | 9.6; 15 | 12; 15 | 9.2; 15 | 12; 15 | 15.4; 15 | 12; 15 | 15.4; 15 | 15.4; Curve: Exact Q/H row references; phase and motor power require matched selection 0323-93 | Electrical irrigation submersible pump Q m³/h | H m: 3 | 11; 3 | 14.2; 3 | 22.5; 3 | 18.5; 3 | 13.2; 3 | 8.5; 3 | 28.5; 3 | 19; 3 | 19; 3 | 12; 3 | 10.5; 3 | 25; 3 | 16.5; 3 | 9.5; 30 | 10.5; 30 | 10.5; 30 | 10.5; 30 | 10.5; 30 | 13.7; 30 | 13.7; Curve: Exact Q/H; first6 configurations single-phase only; other phase variants selected separately 0323-94 | Sewage pump with larger solids passage outlet mm | kW | rated Q m³/h | rated H m | Qmax m³/h | Hmax m | particles mm: 50 | 0.55 | 9 | 6 | 19 | 9.5 | 35; 50 | 0.55 | 13 | 4 | 22 | 6 | 50; 50 | 0.75 | 12 | 8 | 22.5 | 13 | 35; 50 | 0.75 | 15 | 5.5 | 27 | 9 | 50; Phases: Both single/three phase listed; rated Q/H paired; Qmax/Hmax independent 0323-95 | Pressure-sewage submersible pump outlet mm | kW | rated Q m³/h | rated H m | Qmax m³/h | Hmax m: 32 | 1.1 | 3.6 | 17 | 8 | 18; 32 | 1.5 | 3.6 | 23 | 10 | 23.2; 32 | 2.2 | 3.6 | 30 | 12 | 30.2; Phases: Both single/three phase listed; rated Q/H paired; Qmax/Hmax independent 0323-96 | Sewage pump with compact solids passage outlet mm | kW | rated Q m³/h | rated H m | Qmax m³/h | Hmax m | particles mm: 50 | 0.55 | 6 | 12 | 19 | 15 | 20; 50 | 0.75 | 6 | 16 | 22 | 19 | 20; 50 | 0.75 | 10 | 10 | 20 | 15 | 20; 50 | 1.1 | 8 | 16 | 26 | 19 | 15; 50 | 1.5 | 8 | 20 | 25 | 22 | 15; 50 | 2.2 | 15 | 20 | 45 | 23 | 25; 50 | 3 | 15 | 25 | 51 | 27 | 25; Phases: First6 duties single/three phase; last3kW three-phase only; independent maxima 0323-97 | Submersible peripheral well-water pump Power kW: 0.37; Configuration order — Q m³/h → H m (same curve point): 1: 1→20; Limits: Liquid40°C; immersion5m; pH6.5–8.5; sand≤0.1%; particles≤0.2mm 0323-98 | Double-casing multistage process pump Series envelope: Q3–1200m³/h; pressure up to42.0MPa; head up to3600m; −80 to+450°C; different configurations 0323-99 | Large and medium submersible sewage system 0323-100 | Vertical self-priming process pump 0323-101 | RO and ultrafiltration vertical multistage pump 0323-102 | Municipal and industrial submersible sewage pump 0323-103 | Cast-iron submersible sewage pump Construction: 0.25–4/5.5–7.5kW cast-iron groups;11–45kW group has material alternatives; probes optional 0323-104 | Domestic wastewater lifting station Power W: 600; Configuration order — Q m³/h → H m (same curve point): 1: 4.5→4.5; Limits: 600W; liquid≤50°C; ambient≤35°C; pH4–10; no corrosive chemicals or solvents 0323-105 | Split-case double-suction fire-water pump Rated Q L/s: pressure MPa / motor kW: 40: 0.3/18.5, 0.35/22, 0.4/30, 0.48/30; 50: 0.35/30, 0.42/37, 0.48/45, 0.53/45, 0.58/55, 0.64/55, 0.7/55, 0.81/75, 0.86/75, 0.91/75; 60: 0.38/37, 0.48/45, 0.58/55, 0.66/75, 0.73/75, 0.82/90, 0.9/90, 1.0/110, 1.08/110; 70: 0.42/55, 0.5/55, 0.6/75, 0.66/75, 0.81/90, 0.96/110, 1.12/132; 80: 0.5/75, 0.56/75, 0.65/90, 0.75/110, 0.91/132, 1.0/132, 1.11/160; 100: 0.37/75, 0.43/75, 0.5/90, 0.55/90, 0.6/110, 0.7/132, 0.78/132, 0.87/160, 1.0/160, 1.08/185, 1.12/185; Reference: 2950rpm; project approval and current matched curve required 0323-106 | Stainless standard centrifugal pump kW | Q m³/h | H m: 1.1 | 12 | 19.5; 1.5 | 12 | 25; 2.2 | 12 | 32; 3 | 12 | 38; 4 | 12 | 49; 1.5 | 30 | 12.5; 2.2 | 30 | 19.5; 3 | 30 | 24; 4 | 30 | 31; 5.5 | 30 | 39; 7.5 | 30 | 48; 3 | 60 | 13; 4 | 60 | 17; 5.5 | 60 | 24; 7.5 | 60 | 29; 11 | 60 | 39.5; 11 | 60 | 47; 4 | 60 | 14; 5.5 | 60 | 18; 7.5 | 60 | 23.5; 11 | 60 | 28; 11 | 60 | 33; 15 | 60 | 41; 18.5 | 60 | 49; 22 | 60 | 55; Curve: Exact same-row Q/H references; optional motor efficiency class requires a specified quotation 0323-107 | Centrifugal water pump for 60 Hz supply V | kW | Q m³/h | H m: 220–230/440–460 | 5.5 | 15 | 63; 220–230/440–460 | 7.5 | 15 | 85; Electrical: 60Hz;220–230/440–460V; exact paired Q/H 0323-108 | Horizontal single-stage project water pump 0323-109 | Standard clean-water centrifugal pump 0323-110 | Stainless borehole water-pump direction 0323-111 | Alternate borehole water-pump direction 0323-112 | Compact centrifugal pump for 60 Hz supply kW | Q m³/h | H m: 0.37 | 6 | 10.41; 0.55 | 6 | 14.85; 0.75 | 6 | 20.46; 1.1 | 6 | 24.3; 1.5 | 6 | 26.94; Electrical: 60Hz range; exact Q/H from its own frequency-specific table 0323-113 | Garden submersibles for clean and dirty water W | Qmax m³/h | Hmax m | particles mm | outlet inch: 300 | 10 | 7 | 5 | 1.25; 400 | 12 | 8 | 5 | 1.25; 550 | 14 | 9 | 5 | 1.5; 750 | 16 | 10 | 5 | 1.5; 1000 | 18 | 11 | 5 | 1.5; 300 | 12 | 6 | 25 | 1.25; 400 | 14 | 7 | 25 | 1.25; 550 | 16 | 8 | 35 | 1.5; 750 | 18 | 9 | 35 | 1.5; 1000 | 20 | 10 | 35 | 1.5; 250 | 5.5 | 6 | 5 | 1.25; 400 | 8 | 7 | 5 | 1.25; 500 | 9 | 7 | 5 | 1.25; 750 | 11 | 8 | 5 | 1.25; 1000 | 12 | 12 | 5 | 1.25; Limits: 35°C;IPX8;float;10m cable;4pcs/carton; Qmax/Hmax independent; Immersion: 7m listed for stainless small-particle group; other groups require clarification of suction-depth label 0323-114 | Hybrid AC/DC solar pool pump W | AC V | DC V | Qmax m³/h | Hmax m | PV Voc < V: 900 | 80–280 | 90–200 | 20 | 19 | 430; 1200 | 80–280 | 90–300 | 27 | 19 | 430; Array: PV power≥1.3×pump;2inch in/out;2m cable;AC/DC/Voc distinct; maxima independent 0323-115 | Conventional swimming-pool circulation pump Power W | Q m³/h → H m (same curve point): 250 | 6→2.9; 300 | 6→4.2; 350 | 6→6.2; 450 | 6→7.2; 550 | 9→8; 750 | 9→9.7; 850 | 9→10.5; Limits: Liquid5–50°C;ambient40°C;suction3.5m;F/IPX5; copper or aluminium winding specified per version 0323-116 | DC solar swimming-pool circulation pump W | rated V | input V | Qmax m³/h | Hmax m | PV Voc < V: 500 | 48 | 60–90 | 15 | 14 | 100; 900 | 72 | 90–120 | 20 | 19 | 150; 1200 | 72 | 90–120 | 27 | 19 | 150; 1200 | 110 | 110–150 | 27 | 19 | 200; Array: PV power≥1.3×pump;2inch in/out;2m cable; rated/input/Voc distinct; maxima independent 0323-117 | Pond and fountain circulation pump input W | Qmax L/h | Hmax m | outlet mm: 15 | 850 | 1 | 13; 20 | 1100 | 1.1 | 13; 35 | 1600 | 1.4 | 19; 55 | 2300 | 2.3 | 19; 75 | 2650 | 2.7 | 19; 95 | 3500 | 3 | 19; 110 | 3750 | 3.7 | 19; Electrical: 220–240V50Hz;10m cable; liquid≤35°C;ambient≤40°C; maxima independent 0323-118 | Self-priming cast-iron centrifugal pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 1.1 | 10.2→8.5; 3φ | 1.1 | 10.2→8.5; 1φ | 1.5 | 10.2→13.5; 3φ | 1.5 | 10.2→13.5; Limits: Liquid≤60°C;ambient≤50°C;suction≤8m;F/IPX4 0323-119 | Cast-iron centrifugal transfer pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.75 | 9.6→9; 3φ | 0.75 | 9.6→9; 1φ | 0.6 | 7.8→7.5; 3φ | 0.6 | 7.8→7.5; Limits: Liquid≤60°C;ambient≤50°C;suction≤8m;F/IPX4 0323-120 | Stainless horizontal multistage transfer pump Motor phase | Power kW | Q m³/h → H m (same curve point): 1φ | 0.37 | 3→16.5; 1φ | 0.6 | 3→22; 1φ | 0.75 | 3→31.5; 3φ | 0.75 | 3→31.5; 1φ | 0.9 | 3.6→32; 3φ | 0.9 | 3.6→32; Limits: Liquid≤60°C;ambient≤50°C;suction≤8m;F/IPX4 0323-121 | Self-priming stainless multistage transfer pump Power kW | Q m³/h → H m (same curve point): 0.9 | 3→26; 1.1 | 3→38; 1.3 | 3→45; Limits: Liquid≤35°C;ambient≤50°C;suction≤8m;F/IPX4; mechanical and lip seals 0323-122 | Borehole water-pump assembly direction 0323-123 | Vertical axial-flow irrigation and drainage pump Conditions: Medium≤50°C;clockwise viewed from drive end;single/double foundation;fixed or variable frequency This is a sourcing brief, not a quotation, certification, stock confirmation or guaranteed delivery schedule. Confirm the model-specific specification, minimums, sample approval, costs, lead time and contract terms before ordering.