Coordinate industrial routers, data terminals, gateways, computers, sensing and monitoring systems for water, power, fire, environmental, agricultural, transport and factory applications, with project-specific integration and electronic OEM/ODM enquiries.

  • Match field sensors, radio/network protocols, edge devices and platform requirements
  • Compare water, power, fire and industrial monitoring with the actual installation brief
  • Coordinate configuration, sample validation, documents, software scope and packing

Manufacturing, product documents and order conditions depend on the model and supply route selected for your project.

Generic industrial router, monitoring display and sensor illustration
Category illustration. Confirm the actual article, configuration, intended use, finish, documents and supplied contents.

Start with a product reference, intended use and estimated quantity. We bring product selection, sample questions and quotation details into one conversation.

Email your reference image ↗
Connectivity5G/4G, LPWAN, serial, Ethernet and project-specific networks
System layersSensing, data collection, edge computing, platform and integration
Application scopeWater, power, fire, industry and wider infrastructure monitoring
Quotation basisSite, measurement, interfaces, destination and acceptance requirements
Explore the product range

Build the range
your buyers need.

Choose a focused product or discuss a coordinated assortment. Each direction can be developed into a more specific model and packaging brief.

Industrial communications and computing

Cellular routers, CPE/ODU, smart gateways, DTUs, LPWAN modules/terminals, industrial computers, embedded boards and touch displays support different network and local computing roles.

Enquire about this range ↗

Water resources, irrigation and geology

Telemetry, radar/ultrasonic/submersible/bubbler level sensing, rainfall, flow, soil moisture, GNSS/displacement, vibrating-wire acquisition, gate/well control, warning broadcasts and management platforms cover field monitoring directions.

Enquire about this range ↗

Power communications and distribution monitoring

FTU/DTU communications, encrypted-router directions, communication managers, fault indicators, line-loss modules, power meters, cabinet dehumidification, line imagery/video, acoustic imaging and monitoring platforms can be scoped separately.

Enquire about this range ↗

Water utility instruments and monitoring

Water-quality sensors, leak detection, pressure/level/flow sensing, smart covers/hydrants, remote meters, telemetry, perception platforms and unmanned monitoring-vessel directions serve different network tasks.

Enquire about this range ↗

Fire-system connectivity and monitoring

Electrical and water monitoring, panel networking/protocol cards, smoke/gas/manual/sound-light alarm directions, RFID inspection, wireless transport and command/maintenance software require destination-specific system approval.

Enquire about this range ↗

Industrial intelligence and electronic project services

Industrial sensors, data collection, edge analytics, platforms and integration enquiries can be coordinated alongside separate SMT, assembly, test and OEM/ODM electronic-project directions.

Enquire about this range ↗
Reference product directions

Start with a product.
Define the details.

Use these options to describe what you are buying. The public references identify your enquiry; the final model and specification are confirmed before an order.

Compact serial-and-Ethernet cellular router sourcing illustration
REFERENCE 0379-01

Compact serial-and-Ethernet cellular router

Connect serial instruments and Ethernet equipment through a compact industrial router. Confirm the radio module, firmware, supply and ordered interfaces for the destination.

Ethernet
Two 100Mbps ports
Serial
RS232 and RS485
Housing reference
Aluminium; IP30 listed
VPN directions
IPsec, OpenVPN and WireGuard
Traffic controls
SPI firewall listed; configuration and validation required
Discuss this option ↗
Compact 5G and RedCap router sourcing illustration
REFERENCE 0379-02

Compact 5G and RedCap router

Review a compact router for embedded installations, private-network access and remote administration. Carrier bands, enabled functions and antenna arrangements depend on the selected variant.

Network directions
SA/NSA and RedCap; APN/VPDN
Wi-Fi reference
2.4G and 5.8G dual-band as listed
Dimensions
106 × 76 × 23.5mm
Mass
285g
Network functions to approve
Cell/frequency locking, bridge, virtual IP, GRETAP, 5G LAN, VXLAN and EOIP
Interfaces / VPN
Gigabit Ethernet, serial and Wi-Fi; IPsec/PPTP/GRE/L2TP/OpenVPN directions
Discuss this option ↗
5G router with CAN and positioning sourcing illustration
REFERENCE 0379-03

5G router with CAN and positioning

Select this direction where serial/CAN devices and location information need a cellular link. Confirm connector definitions, radio coverage and the required firmware functions.

Radio
SA/NSA and RedCap directions
Local interfaces
Serial, CAN and GPS listed
Wi-Fi reference
2.4G and 5.8G dual-band
Listed working temperature
−35°C to +75°C
Networking
Gigabit Ethernet, VPN and remote-management directions
Discuss this option ↗
LTE Cat.1 serial data terminal sourcing illustration
REFERENCE 0379-04

LTE Cat.1 serial data terminal

Provide serial equipment with a cellular data path for lower-to-medium data-rate applications. Third-party MQTT access requires the corresponding software version and integration review.

Network
LTE Cat.1
Data path
Serial-to-cellular transparent transmission
Server arrangement
Up to five data centres listed; actual mode to approve
Integration
Standard MQTT platform connection; firmware/version to confirm
Discuss this option ↗
Indoor LoRaWAN gateway sourcing illustration
REFERENCE 0379-05

Indoor LoRaWAN gateway

Match the sensor protocol and regional radio plan with the network server. A private-protocol LoRa network and a LoRaWAN deployment need separate compatibility approval.

Supply choices
DC 5–36V or PoE+
Listed classes
Class A and Class C; starred Class B requires confirmation
Server modes
Embedded network server, Basic Station or Semtech UDP GWMP
Platform directions
ChirpStack, TTN, LinkWAN and other compatible integrations
Network options
APN/VPDN and VPN directions; actual version to approve
Discuss this option ↗
Fanless industrial computing box sourcing illustration
REFERENCE 0379-06

Fanless industrial computing box

Coordinate computing, display and field-device interfaces for a local IoT application. Confirm the operating system, memory/storage, expansion and enclosure requirements on the chosen configuration.

Processor direction
RK3288 quad-core
Construction
Metal enclosure; fanless design
Display / peripherals
HDMI/LVDS, USB, audio and GPS directions
Field interfaces
RS232/RS485, I/O, analogue input and CAN directions
Connectivity
4G networking direction; current module and software to approve
Discuss this option ↗
Battery-powered pipe-network telemetry terminal sourcing illustration
REFERENCE 0379-07

Battery-powered pipe-network telemetry terminal

Combine remote data collection, storage, reporting and threshold alarms for pipe-network or well monitoring. Match sensors, reporting frequency, power budget and installation conditions.

Measured inputs
Pressure, flow, level and velocity sensor directions
Sensor matching
Radar/ultrasonic level meters and other compatible third-party sensors
Communications
Cellular, NB-IoT/Cat.1 or LoRa variants to approve
Power / operating modes
Replaceable battery; self-report, query and compatible modes
Setup
Configurable collection/report intervals, GNSS and local configuration directions
Discuss this option ↗
Non-contact radar water-level instrument sourcing illustration
REFERENCE 0379-08

Non-contact radar water-level instrument

Use a non-contact radar direction for rivers, reservoirs, drainage or level-monitoring projects. Confirm the measurement geometry, mounting, reference target and calibration conditions.

Principle
FMCW radar; non-contact installation
Listed measuring range
0.1–40m
Listed accuracy
Up to ±2mm; actual conditions and verification required
Application role
Water-level monitoring; no legal-metrology approval implied
Discuss this option ↗
Distribution energy-loss measurement module sourcing illustration
REFERENCE 0379-09

Distribution energy-loss measurement module

Review energy measurement and communications alongside the distribution terminal. Measurement, reporting and mechanical integration can be assessed for the actual project.

Measurement directions
Three-phase forward/reverse active energy and four-quadrant reactive energy
Stored reference
Previous 12 assessment-day bidirectional total-energy records
Event / freeze functions
Direction-change and other events; timed, instantaneous, daily and hourly freezes
Communication
RS232 or RS485; DL/T 634.5101-2002 protocol listed
Customization
Measurement, metering and communication functions subject to feasibility
Discuss this option ↗
Modular multifunction power instrument sourcing illustration
REFERENCE 0379-10

Modular multifunction power instrument

Compare electrical measurements, power-quality information, event records and remote control with the installation brief. Expansion is optional rather than included on every item.

Functions
Parameter measurement/statistics, power-quality analysis and event records
Communication choices
Serial or LoRa/NB-IoT/cellular directions
Optional expansion
AI/AO/DI/DO/COM/Ethernet module directions
Approval basis
Current measuring ranges, accuracy, CT/PT ratios, supply and panel cutout
Discuss this option ↗
Digital online pH sensor sourcing illustration
REFERENCE 0379-11

Digital online pH sensor

A flat-front electrode and automatic temperature compensation support an online monitoring arrangement. Specify the medium, calibration and maintenance conditions before selection.

Measuring range / accuracy
0–14pH / ±0.1pH listed
Resolution
0.01
Communication
RS485; Modbus
Housing / mounting
POM; immersion type; Φ26 × 167.5mm
Listed environmental limits
IP68; up to 10m underwater; operating 0–50°C without freezing
Power
DC 5–12V; current <50mA
Cable / calibration
10m cable; three-point calibration
Storage
0–60°C without freezing
Discuss this option ↗
Stainless pipe-pressure transmitter sourcing illustration
REFERENCE 0379-12

Stainless pipe-pressure transmitter

Select a pressure type, span, electrical output and compatible wetted arrangement together. Catalogue span alternatives are separate configurations, not one automatically switching range.

Span selection references
A: 0–0.35bar … 200bar; B: 0–250bar … 600bar; exact span to approve
Pressure types
Gauge, absolute or sealed gauge
Listed accuracy / overload
±0.5%FS / 1.5 × full-scale pressure
Current-output configuration
4–20mA, two-wire; DC 8–30V
Voltage-output configurations
0–10, 0.5–4.5, 0–5 or 1–5V; three-wire, DC 12–30V
Temperature references
Compensation 0–70°C; working −10–70°C; storage −40–80°C
Construction / mass
Stainless structure; IP65; ≤150g listed
Discuss this option ↗
Residual-current electrical monitoring terminal sourcing illustration
REFERENCE 0379-13

Residual-current electrical monitoring terminal

Coordinate a front-end electrical monitor with the alarm platform and site requirements. Applicable installation, protection roles and conformity evidence must be established for the ordered system.

Inputs listed
One three-phase voltage group, one three-phase current group, one residual-current input and four temperature inputs
Communications
RS485 or optional CAN; cellular/NB-IoT/LoRa/LoRaWAN directions to approve
Functions
Display, threshold warning, sound/light alarm and remote management directions
Project basis
Sensor ratios, alarm thresholds, supply, interfaces and applicable documents
Discuss this option ↗
Programmable smart-pole gateway sourcing illustration
REFERENCE 0379-14

Programmable smart-pole gateway

Connect pole-mounted equipment through an integration gateway. Provide the peripheral schedule and data/protocol requirements so interface allocation and software work can be reviewed.

Backhaul choices
5G/4G, optical fibre or wired communication directions
Interfaces
Gigabit fibre/Ethernet, serial and Wi-Fi directions
Development
Python and C development environments listed
Protocol service
Private communication-protocol customization subject to feasibility
Listed working temperature
−35°C to +75°C
Discuss this option ↗
Wireless temperature-and-humidity sensor direction sourcing illustration
REFERENCE 0379-15

Wireless temperature-and-humidity sensor direction

Compare a wall-mounted wireless sensor with the required measurement range, reporting interval and gateway protocol. Confirm the current sensor element and calibration file before ordering.

Construction
Integrated ABS enclosure; LCD; wall mounting
Listed enclosure reference
IP65
Radio choices
433/470/868/915MHz; default and regional variant to approve
Protocol direction
Private LoRa or LoRaWAN compatibility to verify
Power
Replaceable 4000mAh lithium-thionyl-chloride battery listed; runtime depends on configuration
Discuss this option ↗
Outdoor 5G CPE direction sourcing illustration
REFERENCE 0379-16

Outdoor 5G CPE direction

Review an outdoor cellular CPE with the mounting, power and local interface requirements. Confirm the exact radio and Wi-Fi specification and complete installed enclosure arrangement.

Network
SA/NSA; APN/VPDN and private-network functions listed
Interfaces
One RS232, one RS485, one gigabit LAN and one gigabit WAN
Power / positioning
PoE and GPS directions
Enclosure reference
IP68 listed; actual installed configuration and records required
Control
Remote administration, VPN and access-control directions
Discuss this option ↗
LPWAN modules, gateways and sensing terminals sourcing illustration
REFERENCE 0379-17

LPWAN modules, gateways and sensing terminals

Coordinate a complete low-power network rather than mixing incompatible protocols. Regional frequencies, server arrangement, sensor payload and power requirements define the configuration.

Network families
Private-protocol LoRa, LoRaWAN, NB-IoT and ZigBee directions
Hardware roles
Modules, data terminals, indoor/outdoor gateways and base stations
Sensing directions
Temperature/humidity, vibration and general low-power sensor terminals
Discuss this option ↗
Industrial video, Ethernet and vehicle connectivity sourcing illustration
REFERENCE 0379-18

Industrial video, Ethernet and vehicle connectivity

Source complementary networking devices alongside the gateway and platform. Specify cameras, storage, data retention, lawful access and the intended system interfaces.

Network hardware
Industrial Ethernet switches
Video roles
Cameras, network video recorders and AI video boxes
Mobile / infrastructure roles
Vehicle positioning, inertial navigation and smart-pole gateways
Discuss this option ↗
Industrial sensing, edge analytics and platform integration sourcing illustration
REFERENCE 0379-19

Industrial sensing, edge analytics and platform integration

Prepare an asset-monitoring or predictive-maintenance brief linking sensing, data acquisition and application workflows. Scope the equipment, software licences and integration responsibilities explicitly.

System directions
Industrial sensors, data acquisition, edge computing and industrial cameras
Execution directions
Collaborative robotic-arm and AGV integration enquiries
Software directions
IoT PaaS, visualisation, rules, open API, time-zone handling and alarm workflows
Discuss this option ↗
Electronic assembly and OEM/ODM project direction sourcing illustration
REFERENCE 0379-20

Electronic assembly and OEM/ODM project direction

Submit the electronic design and assembly brief for feasibility review. Distinguish a board-assembly task from a complete tested product and define the acceptance, sourcing and packing responsibilities.

Process directions
SMT, through-hole/soldering, final assembly, testing and packing
Customization
OEM/ODM electronic-product enquiries
Inspection directions
AOI and ICT; safety, reliability, environmental and ageing-test arrangements to specify
Discuss this option ↗

These are selected technical references and broader project directions. Confirm the actual hardware revision, radio region, optional interfaces, firmware/licences, measurement conditions, documents and acceptance file. Other listed product families can be included in an enquiry without assuming unreviewed variant specifications.

What matters for this category

A better brief.
A clearer comparison.

Focus the sourcing conversation on the features, materials and production details that make a difference to your product range.

01

A connected procurement brief

Coordinate the measurement point, communications path, edge processing and application platform so hardware and software interfaces are addressed together.

02

Compare different field environments

Build separate briefs for indoor cabinets, outdoor sites, pipe networks, water instruments and industrial installations. Approve the actual enclosure, power and environmental limits.

03

Include integration from the start

Define protocol mapping, firmware, remote administration, APIs, data ownership, alarms and validation alongside the device selection.

Branding, configuration & packaging

Make the product
fit your programme.

Bring artwork, reference samples and a target cost. The available process, minimum quantity, sample charges and development scope are reviewed for the chosen option.

01

Hardware and network configuration

Provide radio bands/operators, SIM/network plan, supply, interfaces, sensors, mounting and environment. Confirm antenna, enclosure, wiring and any private-protocol or development work for the chosen item.

02

Platforms and electronic OEM/ODM

Describe data points, API/platform, user roles, alarms, software deployment and development responsibilities. Electronic assembly or OEM/ODM enquiries need the design/BOM, sourcing scope and acceptance requirements.

03

Sample, presentation and packing

Request an appropriate evaluation unit or project test plan. Agree lawful labelling/manuals, accessories, ESD/moisture/mechanical protection, carton contents and shipping documents; quantities, costs and timing require a current quotation.

Quality & product evidence

Turn requirements
into checks.

Agree which product characteristics need testing and how the approved sample relates to the bulk order.

01

Validate the actual configuration

Check the ordered radio module, software revision, sensor span, I/O, supply and accessories against an approved technical file. Test communications and recovery behaviour in the intended system.

02

Agree measurable acceptance

Specify calibration, measurement conditions, enclosure installation and electrical/environmental tests relevant to the item. Define inspection sampling, serial traceability and acceptance records.

03

Keep compliance tied to the item

Request current destination and application evidence for the exact equipment and responsible supplying entity. Fire, hazardous-area, utility or other specialist installations need their own approval process.

Test capability is a starting point for the inspection plan. Request the method, applicable model and results needed for your order.

Documents matched to the order

Ask for evidence
that fits the product.

Send the site, required measurements, network plan, interfaces and destination to define the current technical, software, conformity and delivery file.

State the sales market, intended users and required files in your first enquiry. Current validity and scope are checked for the selected supplier and product; a category description does not certify every item.

Share your document requirements ↗
Device and interface records
Request the actual datasheet, dimensions/mounting, wiring, I/O mapping, radio bands, antenna and power requirements, measurement/calibration information and accessory list.
Software and integration records
Request supported protocol/version details, API/interface documents, firmware/licence scope, remote-access configuration, update process, data/security responsibilities and commissioning instructions.
Conformity and shipment file
Request applicable current tests/certificates for the selected item and destination, inspection/sample approval, packing list, serial identification and operating/maintenance documentation.
Built around how you sell

Different buyers.
Different specifications.

Your sales channel changes the assortment, packaging and quality priorities. Tell us the intended use as well as the product name.

01

Water resources and flood-monitoring networks

Rainfall, water level, flow, telemetry, local storage, satellite/cellular communications and warning-broadcast requirements can be coordinated with a current project design.

02

Irrigation, gates, pumps and weather stations

Specify water/soil/weather measurements, pump electrical data, gate state/control and video needs, together with site power and communication availability.

03

Raw water, supply, drainage and wastewater

Scope water-quality, pressure/flow/level, leak detection, pump rooms, network monitoring and urban waterlogging information with the applicable sensors and platform.

04

Agriculture and livestock environments

Combine environmental/soil sensing, video and remote control requirements for planting or husbandry. AI features need the specific dataset, conditions and acceptance definition.

05

Transport and infrastructure

Vehicle connectivity, smart poles and dynamic weighing/video integration are project directions. Define lawful data collection, interfaces and installation requirements.

06

Geological and structural monitoring

GNSS/displacement, settlement, rainfall, soil/water conditions and rockfall-monitoring directions require a site-engineered layout, baseline, calibration and warning workflow.

07

Fire monitoring and digital maintenance

Define electrical/water/panel/alarm connectivity, inspection workflows and responsible operations alongside the applicable local approval and commissioning requirements.

08

Power rooms and distribution networks

Integrate electrical/environmental information, communications, fault/line monitoring and remote operations within the utility or facility requirements.

09

Environmental equipment supervision

Monitor production and pollution-treatment equipment electricity/status information with the agreed instrumentation, reporting and data-use requirements.

10

Marine environmental monitoring

Water quality, current, wave and weather sensing on buoy-monitoring projects requires site-specific materials, power, positioning and data-transmission planning.

11

Industrial assets and factory workflows

Coordinate sensors, data acquisition, industrial cameras, edge processing and platform alarms for condition monitoring or operational workflows. Validate analytics on the actual application.

From first brief to a defined order

One contact.
A practical next step.

Samples, commercial terms and responsibilities are agreed for the project. Use the same product and packing specification when comparing quotations.

01

Share the requirement

Product, reference image, quantity, sales market and timing.

02

Compare suitable options

Review configuration, materials, sample scope and relevant documents.

03

Approve the specification

Agree artwork, packaging, sample, testing and inspection criteria.

04

Confirm the order plan

Set price, payment, production, delivery and defect remedies in writing.

Buyer questions

Before you send
your first enquiry.

Practical answers about this sourcing direction, customization and the reference options. Your agreed specification and written quotation determine the actual order.

Which product and system directions are available?

Industrial communications/computing, water resources and utility instruments, power monitoring, fire connectivity and industrial sensing/platform directions can be coordinated. Separate electronic assembly/OEM/ODM enquiries can also be reviewed.

How do I choose between LoRa and LoRaWAN?

Specify the exact terminal protocol, radio region and gateway/server arrangement. Private-protocol LoRa and LoRaWAN are different integration choices; compatible frequency alone does not establish interoperability.

Are all cellular versions usable in every country?

Provide the destination, operators, bands, network mode, SIM/APN plan and applicable approvals. Confirm the exact radio module, antennas and firmware before approving a configuration.

Can existing serial equipment or third-party sensors be connected?

Send the interface, protocol/version, registers, electrical levels, sensor output, reporting rate and power requirements. Compatibility and any protocol-development work must be confirmed on the chosen hardware/software.

Can cloud access, API or custom software be included?

Describe deployment, data ownership, user roles, alarms, remote access, APIs and update responsibilities. Confirm licences, integration scope, software version and acceptance tests in the quotation.

Can you coordinate evaluation samples or electronic OEM/ODM?

Request an evaluation configuration or provide the design/BOM and assembly brief. Feasibility, sample/test work, sourcing responsibilities, quantities, costs and timing depend on the actual project.

Do enclosure ratings or catalogue accuracy prove suitability for my site?

Approve the actual item, mounting/wiring, medium, environmental limits and applicable test/calibration evidence. Fire, hazardous-area and utility uses need their own destination-specific review and commissioning.

What should I send for a complete quotation?

Send the application/site, measurements and ranges, network/protocol plan, I/O and supply, quantities and destination. Include software, sample/validation, documentation, lawful presentation, packing and shipment requirements.

Who handles my enquiry?

Factory Sourcing Hub handles this enquiry as an independent sourcing and trading service. The product route, supplier suitability, sample scope and order responsibilities are agreed for the actual project.

How do I get a price and order minimum?

Send the product reference, quantities per variation, customization and packaging. Prices, minimums, sample charges and delivery dates are confirmed in a current quotation; the page is not a live inventory or price feed.

Can I discuss samples and inspection before ordering?

Yes. State whether you need a reference sample, a customized sample or development work. Agree the sample cost and shipping, approval specification, inspection plan and remedy for non-conforming goods before the bulk order.

What should I attach to my email?

Reference images, drawings, logo artwork and a product list are useful. Include quantities, the intended users and sales market, packaging, required documents and timing. After submitting the form, email attachments to kunhuow@gmail.com with your enquiry reference.

Tell us what you are planning

Your next order
starts with a brief.

A reference picture or a short description is enough to begin. Add the details you already know; the optional fields help make the follow-up more useful.

  • Application/site, measured variables/ranges, environment and destination
  • Radio/operator/protocol plan, sensor I/O, supply, mounting and data/reporting needs
  • Hardware/software scope, quantities, evaluation, acceptance and current documentation
  • Lawful labels/manuals, included accessories, protective packing and requested shipment window
kunhuow@gmail.com

Download the enquiry checklist ↓

Independent sourcing and trading service. Supplier choice, service costs and order conditions are discussed for your project.

Discuss your requirements.

Product selection, customization, samples and quotation enquiries.

Add product, quantity or customization details (optional)

Submit your enquiry directly. We use your details to respond to your sourcing request. For attachments, email kunhuow@gmail.com with your enquiry reference. Enquiry data use.

Information basis: published product information reviewed . Reference details support a sourcing discussion. Current supply, samples and product-specific documents are confirmed for the selected item.

Have a product in mind?
Share your sourcing brief.
Send an enquiry ↗